scp81: BER length for the Response Scripting template TLVs (v2.1.17)

The R-APDU TLV length was read as a raw byte, so a listing page above 127
bytes (AF 80 23 81 FC <252 bytes> 00 00) was cut to its first 127 bytes with
a bogus status word (the data's last two bytes: CAFE/0001/9F70 instead of
the real 63 10 "more data"). The bogus SW also stopped the SW CAFE/6310
pagination, which is why later registry entries - e.g. the installed package
AA1902BC225801 - never showed up. Uses httpota.ber_len_read now.

Tests: 250-byte long-form page and short-form regression (204 python);
findings updated; service worker v154
This commit is contained in:
2026-09-16 08:29:00 +03:00
parent c341571300
commit e957757fda
6 changed files with 48 additions and 8 deletions
+11 -5
View File
@@ -21,7 +21,7 @@ from osmocom.construct import GsmOrUcs2Adapter
from osmocom.tlv import BER_TLV_IE
VERSION = '2.1.16'
VERSION = '2.1.17'
MAX_ENVELOPE_SEGMENTS = 5 # max SMS segments for outgoing C-APDU in ENVELOPE
@@ -1479,10 +1479,16 @@ def _scp81_parse_response(body):
content = body
count, out = 0, []
off = 0
while off + 1 < len(content):
tag, tlen = content[off], content[off + 1]
val = content[off + 2:off + 2 + tlen]
off += 2 + tlen
while off < len(content):
tag = content[off]
# BER lengths: an R-APDU TLV above 127 bytes is `23 81 FC ...`; a raw
# byte >0x7F used as a length silently truncated every listing page
# to 127 bytes (live 2026-09-16), hiding later registry entries.
tlen, voff = httpota.ber_len_read(content, off + 1)
val = content[voff:voff + tlen]
if len(val) < tlen:
break
off = voff + tlen
if tag == 0x80:
count = int.from_bytes(val, 'big') if val else 0
elif tag == 0x23 and len(val) >= 2: