forked from public/pysim
smpp-ota-tool: add --format compact,expanded for TS 102 226 5.2
Add --format expanded flag to send C-APDUs in the expanded remote application data format. Each --apdu becomes its own C-APDU TLV, and the tool logs the full per-command R-APDU list decoded from the Response Scripting template and warns if the card reports a truncated response. Default stays 'compact', unchanged. Change-Id: Idad90756f85bb7e54ef720f6067bb5d6dcff0c42
This commit is contained in:
@@ -170,6 +170,35 @@ ensures that a message can only be sent once.
|
||||
.. note:: The replay-protection-counter is implemented as a 5 byte integer value (see also ETSI TS 102 225, Table 3).
|
||||
When the counter has reached its maximum, it will not overflow nor can it be reset.
|
||||
|
||||
Expanded remote application data format
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
`smpp-ota-tool` uses the TS 102 226 section 5.1 compact remote application data format by default. This
|
||||
format concatenates C-APDUs into one command string and only the result of the LAST executed command is reported back.
|
||||
Retrieving the response data therefore requires a GET RESPONSE C-APDU, and only a single GET RESPONSE command may occur per script.
|
||||
|
||||
The TS 102 226 section 5.2 expanded remote application data format removes these limitations: Each C-APDU is
|
||||
wrapped in its own C-APDU TLV inside a Command Scripting template, and the response is a Response Scripting template that contains one R-APDU TLV with the full response data and status word per executed command. To use it, pass
|
||||
``--format expanded``; every ``--apdu`` argument then becomes its own C-APDU TLV.
|
||||
|
||||
.. note:: The expanded format does not use GET RESPONSE. To retrieve response data from a case 2 or case 4
|
||||
command, include an ``Le`` field in the C-APDU. i.e. ``Le='00'`` instructs the card to return all available
|
||||
response data in the R-APDU, with no 256-byte limit (TS 102 226, section 5.2.1.1). Without the ``Le``
|
||||
field no response data is returned, except a status word for the last command!.
|
||||
|
||||
For example, a GP GET STATUS of all applications (``80F24002024F00``) returns a registry that can be much
|
||||
larger than 256 bytes. In the compact format the card would only answer with ``61xx`` procedure bytes. In the expanded
|
||||
format, appending ``Le='00'`` (i.e. ``80F24002024F0000``) makes the card return the whole registry in one exchange:
|
||||
|
||||
::
|
||||
|
||||
$ PYTHONPATH=./ ./contrib/smpp-ota-tool.py --kic <KIC> --kid <KID> --kid-idx 1 --kic-idx 1 \
|
||||
--algo-crypt triple_des_cbc2 --algo-auth triple_des_cbc2 --tar 000000 --cntr-req no_counter \
|
||||
--format expanded --apdu 80F24002024F0000
|
||||
|
||||
The response data (a concatenation of GlobalPlatform registry TLVs) can then be decoded with
|
||||
``pySim.global_platform.GpRegistryRelatedData.from_tlv()``.
|
||||
|
||||
smpp-ota-tool syntax
|
||||
~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
|
||||