mirror of
https://gitea.osmocom.org/sim-card/pysim.git
synced 2026-03-16 18:38:32 +03:00
At the moment we use random identifiers as names when we create a new logger for pySimLogger. Let's switch to consistently use the module name here. For the top level modules let's use the program name so that it will show up in the log instead of __init__. Change-Id: I49a9beb98845f66247edd42ed548980c97a7151a
122 lines
5.1 KiB
Python
Executable File
122 lines
5.1 KiB
Python
Executable File
#!/usr/bin/env python3
|
|
|
|
# (C) 2025 by sysmocom - s.f.m.c. GmbH
|
|
# All Rights Reserved
|
|
#
|
|
# Author: Philipp Maier <pmaier@sysmocom.de>
|
|
#
|
|
# This program is free software: you can redistribute it and/or modify
|
|
# it under the terms of the GNU General Public License as published by
|
|
# the Free Software Foundation, either version 2 of the License, or
|
|
# (at your option) any later version.
|
|
#
|
|
# This program is distributed in the hope that it will be useful,
|
|
# but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
# GNU General Public License for more details.
|
|
#
|
|
# You should have received a copy of the GNU General Public License
|
|
# along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
import unittest
|
|
import logging
|
|
from pySim.log import PySimLogger
|
|
import io
|
|
import sys
|
|
from inspect import currentframe, getframeinfo
|
|
|
|
log = PySimLogger.get(__name__)
|
|
|
|
TEST_MSG_DEBUG = "this is a debug message"
|
|
TEST_MSG_INFO = "this is an info message"
|
|
TEST_MSG_WARNING = "this is a warning message"
|
|
TEST_MSG_ERROR = "this is an error message"
|
|
TEST_MSG_CRITICAL = "this is a critical message"
|
|
|
|
expected_message = None
|
|
|
|
class PySimLogger_Test(unittest.TestCase):
|
|
|
|
def __test_01_safe_defaults_one(self, callback, message:str):
|
|
# When log messages are sent to an unconfigured PySimLogger class, we expect the unmodified message being
|
|
# logged to stdout, just as if it were printed via a normal print() statement.
|
|
log_output = io.StringIO()
|
|
sys.stdout = log_output
|
|
callback(message)
|
|
assert(log_output.getvalue().strip() == message)
|
|
sys.stdout = sys.__stdout__
|
|
|
|
def test_01_safe_defaults(self):
|
|
# When log messages are sent to an unconfigured PySimLogger class, we expect that all messages are logged,
|
|
# regardless of the logging level.
|
|
self.__test_01_safe_defaults_one(log.debug, TEST_MSG_DEBUG)
|
|
self.__test_01_safe_defaults_one(log.info, TEST_MSG_INFO)
|
|
self.__test_01_safe_defaults_one(log.warning, TEST_MSG_WARNING)
|
|
self.__test_01_safe_defaults_one(log.error, TEST_MSG_ERROR)
|
|
self.__test_01_safe_defaults_one(log.critical, TEST_MSG_CRITICAL)
|
|
|
|
@staticmethod
|
|
def _test_print_callback(message):
|
|
assert(message.strip() == expected_message)
|
|
|
|
def test_02_normal(self):
|
|
# When the PySimLogger is set up with its default values, we expect formatted log messages on all logging
|
|
# levels.
|
|
global expected_message
|
|
PySimLogger.setup(self._test_print_callback)
|
|
expected_message = "DEBUG: " + TEST_MSG_DEBUG
|
|
log.debug(TEST_MSG_DEBUG)
|
|
expected_message = "INFO: " + TEST_MSG_INFO
|
|
log.info(TEST_MSG_INFO)
|
|
expected_message = "WARNING: " + TEST_MSG_WARNING
|
|
log.warning(TEST_MSG_WARNING)
|
|
expected_message = "ERROR: " + TEST_MSG_ERROR
|
|
log.error(TEST_MSG_ERROR)
|
|
expected_message = "CRITICAL: " + TEST_MSG_CRITICAL
|
|
log.critical(TEST_MSG_CRITICAL)
|
|
|
|
def test_03_verbose(self):
|
|
# When the PySimLogger is set up with its default values, we expect verbose formatted log messages on all
|
|
# logging levels.
|
|
global expected_message
|
|
PySimLogger.setup(self._test_print_callback)
|
|
PySimLogger.set_verbose(True)
|
|
frame = currentframe()
|
|
expected_message = __name__ + "." + str(getframeinfo(frame).lineno + 1) + " -- DEBUG: " + TEST_MSG_DEBUG
|
|
log.debug(TEST_MSG_DEBUG)
|
|
expected_message = __name__ + "." + str(getframeinfo(frame).lineno + 1) + " -- INFO: " + TEST_MSG_INFO
|
|
log.info(TEST_MSG_INFO)
|
|
expected_message = __name__ + "." + str(getframeinfo(frame).lineno + 1) + " -- WARNING: " + TEST_MSG_WARNING
|
|
log.warning(TEST_MSG_WARNING)
|
|
expected_message = __name__ + "." + str(getframeinfo(frame).lineno + 1) + " -- ERROR: " + TEST_MSG_ERROR
|
|
log.error(TEST_MSG_ERROR)
|
|
expected_message = __name__ + "." + str(getframeinfo(frame).lineno + 1) + " -- CRITICAL: " + TEST_MSG_CRITICAL
|
|
log.critical(TEST_MSG_CRITICAL)
|
|
|
|
def test_04_level(self):
|
|
# When the PySimLogger is set up with its default values, we expect formatted log messages but since we will
|
|
# limit the log level to INFO, we should not see any messages of level DEBUG
|
|
global expected_message
|
|
PySimLogger.setup(self._test_print_callback)
|
|
PySimLogger.set_level(logging.INFO)
|
|
|
|
# We test this in non verbose mode, this will also confirm that disabeling the verbose mode works.
|
|
PySimLogger.set_verbose(False)
|
|
|
|
# Debug messages should not appear
|
|
expected_message = None
|
|
log.debug(TEST_MSG_DEBUG)
|
|
|
|
# All other messages should appear normally
|
|
expected_message = "INFO: " + TEST_MSG_INFO
|
|
log.info(TEST_MSG_INFO)
|
|
expected_message = "WARNING: " + TEST_MSG_WARNING
|
|
log.warning(TEST_MSG_WARNING)
|
|
expected_message = "ERROR: " + TEST_MSG_ERROR
|
|
log.error(TEST_MSG_ERROR)
|
|
expected_message = "CRITICAL: " + TEST_MSG_CRITICAL
|
|
log.critical(TEST_MSG_CRITICAL)
|
|
|
|
if __name__ == '__main__':
|
|