Hygiene: drop dead code, re-raise SystemError, resource+doc cleanup, add LICENSE
- pd.py: remove _lock_etu_from_edges (long-disabled) and the no-op while-True FIND START wrapper. - pd.py: re-raise SystemError (libsigrokdecode's clean EOF signal) in the six 'except Exception: pass' guards so put()/wait() at end-of-capture exits cleanly instead of being swallowed. - pd.py: fix _measure_clock_period docstring (averages, not robust-min); drop stale 'line 1633' comment; document the synthetic pcap UDP header (zero IP checksum / fixed loopback+ports are intentional). - signal_diagnostic.py: add --max-samples cap + document whole-capture RAM cost; fix stale '--rst/--vcc=ignore' guidance (-> --no-rst/--no-vcc). - tests: make test_valid_cla_interindustry_classes use subTest (was a no-op tuple expression). - start.sh/start.bat: note the -A multi-spec form is sigrok-cli 0.7.x. - Remove stale tests/baseline_new.txt (v1.1.3-era, ATR-included mode). - Add top-level LICENSE (GPL-2.0-or-later).
This commit is contained in:
1 parent
e6ff3a2e14
commit
e1903649a7
7 files changed
+356
-521
No files matched your search
@@ -12,6 +12,9 @@ HOST=127.0.0.1
|
||||
PORT=4729
|
||||
PCAP=""
|
||||
DEBUG=""
|
||||
# Annotation rows to show. The comma-separated "decoder=row,decoder=row"
|
||||
# multi-spec form is sigrok-cli 0.7.x syntax (verified 0.7.2); newer
|
||||
# sigrok-cli uses a different row selector, so pin this if upgrading.
|
||||
ANNOT="iso7816=apdus,iso7816=warnings" # default: decoded APDUs + warnings only
|
||||
LOG=""
|
||||
KLOG=""
|
||||
|
||||
Reference in new issue
Block a user