v3.14.1: the counter probe demands its PoR
_counter_probe_params validates SPI2, forces b1 (PoR required; a caller's
00 becomes 01) and defaults to the RAM listing transport 21; the no-PoR
error names the effective SPI2, and ramSyncCounter posts
ramListingSpi2('40') for the RAM view (the failed operation's transport).
Live 2026-10-02 (NP BAP): the probe had sent the plain SCP80 form's 00
(no PoR) - the card answered the ENVELOPE 9000 and sent nothing, so the
probe stopped after one packet with "card verdict: no PoR".
Docs: docs/api.md, repo AGENTS. sw cache simple-v376.
Tests: 670 Python + 798 frontend green.
This commit is contained in:
+7
-2
@@ -1877,7 +1877,7 @@
|
||||
// ===== Version =====
|
||||
// Single source of truth for the PWA version: shown in the header and used
|
||||
// by the server version check in pysimConnect().
|
||||
const SIMPLE_VERSION = '3.14.0';
|
||||
const SIMPLE_VERSION = '3.14.1';
|
||||
document.getElementById('app-version').textContent = 'v' + SIMPLE_VERSION;
|
||||
|
||||
// ===== Tab switching =====
|
||||
@@ -11323,7 +11323,12 @@ async function ramSyncCounter(presetIdx, view) {
|
||||
const tar = val('sp-tar').replace(/[^0-9a-fA-F]/g, '').toUpperCase();
|
||||
if (tar) body.tar = tar;
|
||||
if (val('sp-spi1')) body.spi1 = val('sp-spi1');
|
||||
if (val('sp-spi2-hex')) body.spi2 = val('sp-spi2-hex');
|
||||
// The probe needs a PoR: use the transport the failed operation used - the
|
||||
// RAM listings pin SPI2 0x21 (ramListingSpi2); a plain send whose SPI2
|
||||
// requested no PoR cannot raise the low-counter notice, so the form's
|
||||
// value is already PoR-requesting here.
|
||||
if (view === 'ram') body.spi2 = ramListingSpi2('40');
|
||||
else if (val('sp-spi2-hex')) body.spi2 = val('sp-spi2-hex');
|
||||
const cntr = val('sp-cntr').replace(/[^0-9a-fA-F]/g, '');
|
||||
if (cntr) body.cntr = cntr;
|
||||