v3.25.3: the card's BIP commands during test runs
The runner's three FETCH/TR sites (the proactive-drain action, the expectation, the cleanup drain) built every TERMINAL RESPONSE from the script, so a card-announced OPEN CHANNEL during a run was answered "performed successfully" without opening a channel - SEND DATA was dropped and RECEIVE DATA returned nothing (silent data loss, broken applet state). _test_step_tr now routes 0x40-0x44 through _handle_bip_command: the terminal answers for real, so the card's channels work inside a run. The script keeps an escape hatch - a respond with `raw` TLVs or a non-ok result wins (the applet error-path tests). The BIP events flow during a run again for the channels the card itself opened: _bip_data_available and _bip_flush_channel_events no longer stop at the run guard (a channel only exists because the card opened it) and the runner flushes the link events after each TR, so an applet's own HTTP/BIP conversation completes inside a scripted run. BIP control stays blocked (409). Tests: the drain/expect/cleanup routing, the raw and non-ok-result overrides, the run-time data-available and link events. 883 frontend + 873 Python; sw cache simple-v427.
This commit is contained in:
@@ -36,7 +36,7 @@ from osmocom.tlv import BER_TLV_IE
|
||||
from osmocom.utils import rpad
|
||||
|
||||
|
||||
VERSION = '3.25.2'
|
||||
VERSION = '3.25.3'
|
||||
|
||||
MAX_ENVELOPE_SEGMENTS = 5 # max SMS segments for outgoing C-APDU in ENVELOPE
|
||||
|
||||
@@ -3557,10 +3557,11 @@ def _bip_data_available(ch):
|
||||
server = _server_ref
|
||||
if not server or not _CARD_CONNECTED or not getattr(server, 'scc', None):
|
||||
return False
|
||||
if _PROACTIVE_BUSY or getattr(server, 'stk_pending', None) or _TEST_RUNNING:
|
||||
# a test run owns the card: the bytes stay un-notified and the
|
||||
# monitor retries on its next tick (v3.25.1)
|
||||
if _PROACTIVE_BUSY or getattr(server, 'stk_pending', None):
|
||||
return False
|
||||
# A test run owns the card, but this event is only ever sent for a
|
||||
# channel the card itself opened - the card's own BIP conversation
|
||||
# continuing - so it flows during a run too (v3.25.3).
|
||||
length = min(len(ch.rx), 0xFF)
|
||||
tlv = bytes([0xB8, 0x02, 0x80 | (ch.id & 0x07), 0x00,
|
||||
0xB7, 0x01, length])
|
||||
@@ -5116,9 +5117,9 @@ def _bip_flush_channel_events(scc):
|
||||
global _FLUSHING_CHANNEL_EVENTS
|
||||
if _FLUSHING_CHANNEL_EVENTS:
|
||||
return
|
||||
if _TEST_RUNNING:
|
||||
# a test run owns the card: the events stay queued (v3.25.1)
|
||||
return
|
||||
# The queued events describe channels the card itself opened: they flow
|
||||
# during a test run too - the card must learn that its link died, else it
|
||||
# waits for the run to end (v3.25.3).
|
||||
if not _BIP_LINK_EVENTS:
|
||||
_BIP.take_pending_events()
|
||||
return
|
||||
@@ -6613,6 +6614,28 @@ def _test_terminal_response(cmd_num, cmd_type, dev_dst, dev_src, cmd_qual, respo
|
||||
cd_tag=cd_tag)
|
||||
|
||||
|
||||
_BIP_CMD_TYPES = (0x40, 0x41, 0x42, 0x43, 0x44)
|
||||
|
||||
|
||||
def _test_step_tr(scc, cmd_num, cmd_type, dev_src, dev_dst, cmd_qual, cd_tag,
|
||||
respond, raw):
|
||||
"""The TERMINAL RESPONSE of a test step for a fetched command: the card's
|
||||
own BIP commands (0x40-0x44) are handled by the terminal, so its channels
|
||||
keep working while a run owns the card (v3.25.3). The script overrides
|
||||
the answer when it carries `raw` TLVs or a non-ok result (an applet error
|
||||
path to test); everything else goes through the scripted answer."""
|
||||
r = respond or {}
|
||||
if cmd_type in _BIP_CMD_TYPES and not r.get('raw') and r.get('result', 0) == 0x00:
|
||||
tr = _handle_bip_command(scc, cmd_num, cmd_type, cmd_qual, raw,
|
||||
dev_src, dev_dst, cd_tag=cd_tag)
|
||||
if tr:
|
||||
_test_log('BIP: the terminal answered %s (0x%02X)'
|
||||
% (PROACTIVE_TYPE_NAMES.get(cmd_type, '?'), cmd_type))
|
||||
return tr
|
||||
return _test_terminal_response(cmd_num, cmd_type, dev_dst, dev_src,
|
||||
cmd_qual, respond, cd_tag=cd_tag)
|
||||
|
||||
|
||||
def _test_run_drain(server, step):
|
||||
"""The proactive drain action: poll STATUS and consume every announced
|
||||
command - the TERMINAL RESPONSE is `first` for the first one, `respond`
|
||||
@@ -6649,10 +6672,11 @@ def _test_run_drain(server, step):
|
||||
if menu:
|
||||
server.sim_menu = menu
|
||||
respond = p['first'] if (not consumed and p.get('first')) else p['respond']
|
||||
tr = _test_terminal_response(cmd_num, cmd_type, dev_dst, dev_src,
|
||||
cmd_qual, respond, cd_tag=cd_tag)
|
||||
tr = _test_step_tr(scc, cmd_num, cmd_type, dev_src, dev_dst, cmd_qual,
|
||||
cd_tag, respond, raw)
|
||||
tr_rv = scc._tp.send_apdu('%s140000%02x%s' % (scc.cat_cla, len(tr), tr.hex()))
|
||||
_test_log('TR=%s -> SW=%s' % (tr.hex().upper(), tr_rv[1]))
|
||||
_bip_flush_channel_events(scc)
|
||||
consumed.append({'type_hex': '%02X' % cmd_type, 'type_name': name,
|
||||
'qualifier': ('%02X' % cmd_qual) if cmd_qual is not None else None,
|
||||
'tr_sw': tr_rv[1], 'raw': raw.hex().upper()})
|
||||
@@ -7204,12 +7228,13 @@ def _test_run_expect(server, step, pending, ctx=None):
|
||||
checks.append(_test_check_result(
|
||||
'Files', sorted(paths) == sorted(want), ', '.join(want),
|
||||
', '.join(paths) or '(none)', c['on_fail']))
|
||||
tr = _test_terminal_response(cmd_num, cmd_type, dev_dst, dev_src, cmd_qual,
|
||||
step['respond'], cd_tag=cd_tag)
|
||||
tr = _test_step_tr(scc, cmd_num, cmd_type, dev_src, dev_dst, cmd_qual,
|
||||
cd_tag, step['respond'], raw)
|
||||
tr_rv = scc._tp.send_apdu('%s140000%02x%s' % (scc.cat_cla, len(tr), tr.hex()))
|
||||
tr_sw = tr_rv[1]
|
||||
_test_log('TR=%s -> SW=%s' % (tr.hex().upper(), tr_sw))
|
||||
_record_tr(log_entry, tr, tr_sw)
|
||||
_bip_flush_channel_events(scc)
|
||||
status = testscript.combine_levels([c['level'] if not c['ok'] else 'ok' for c in checks])
|
||||
result = {'status': status, 'sw': tr_sw, 'data': raw.hex().upper(),
|
||||
'sent': 'TR ' + tr.hex().upper(), 'checks': checks,
|
||||
@@ -7244,9 +7269,10 @@ def _test_drain_pending(scc, fetch_len, result=0x00, max_commands=3):
|
||||
break
|
||||
raw = bytes.fromhex(fdata)
|
||||
cmd_num, cmd_type, dev_src, dev_dst, cmd_qual, cd_tag = _parse_proactive_header(raw)
|
||||
tr = _test_terminal_response(cmd_num, cmd_type, dev_dst, dev_src,
|
||||
cmd_qual, {'result': result}, cd_tag=cd_tag)
|
||||
tr = _test_step_tr(scc, cmd_num, cmd_type, dev_src, dev_dst,
|
||||
cmd_qual, cd_tag, {'result': result}, raw)
|
||||
rv = scc._tp.send_apdu('%s140000%02x%s' % (scc.cat_cla, len(tr), tr.hex()))
|
||||
_bip_flush_channel_events(scc)
|
||||
name = PROACTIVE_TYPE_NAMES.get(cmd_type, '?')
|
||||
answered.append({'name': name, 'type': cmd_type,
|
||||
'raw': raw.hex().upper(), 'tr': tr.hex().upper(),
|
||||
|
||||
Reference in New Issue