PLI date/time responses default to the host clock

Live finding (Network rejection events): the card asks the terminal for the
current date and time (PROVIDE LOCAL INFORMATION, qualifier 03) and our TR
answered "performed successfully" with no data.  TS 102 223 6.4.15 says the
terminal shall return the current date and time, and the 6.8.0 TR structure
requires the Date-Time and Time zone object (8.39) for that qualifier.

- _pli_data_hex(qual): the TR Config dictionary entry wins; when it is empty
  the date/time qualifier is answered from the host clock via _encode_scts
  (the SMS timestamp builder, TP-SCTS coding).
- _build_tr and _DefaultProactiveHandler put the command-specific data objects
  after the Result TLV per the 6.8.0 order (the POLL INTERVAL Duration echo
  too; real terminal responses pin the order: 8103010300 02028281 030100
  0402011E).
- _decode_tr decodes qualifier 03 with the same 8.39 coding (swapped
  semi-octet BCD digits, time-zone sign bit 0x08, 'FF' = unknown); it read
  plain decimal bytes and a 0x80 sign before.
- The PWA PLI dictionary codec for the date/time entry writes the same coding
  (it wrote plain hex bytes and a 0x80 sign), and the TR Config panel notes
  the empty-entry default.  sw cache simple-v351.

Tests: builder vectors (east/west/unknown zone) + dictionary override + the
empty non-date/time qualifier + the object order (PLI and POLL INTERVAL) + the
handler path + the TR decode + a frontend codec round-trip test.
This commit is contained in:
2026-10-01 23:37:26 +03:00
parent 69abbe2fa5
commit ad2a253f2a
5 changed files with 217 additions and 43 deletions
+51 -23
View File
@@ -1919,10 +1919,11 @@ class _DefaultProactiveHandler(ProactiveHandler):
pass
ti_list = self.prepare_response(cmd_obj, 'performed_successfully')
if cmd_type == 0x26 and cmd_qual is not None:
pli_hex = _PLI_DATA.get(cmd_qual, '')
pli_hex = _pli_data_hex(cmd_qual)
if pli_hex:
try:
ti_list.insert(2, _RawBerTlv(pli_hex))
# After the Result, per the TS 102 223 6.8.0 object order.
ti_list.append(_RawBerTlv(pli_hex))
except Exception:
pass
if entry:
@@ -2619,15 +2620,24 @@ def _decode_tr(type_hex, qual_hex, tr_hex):
if qual == 0x01 and len(v) >= 16:
return [{'label': 'IMEI', 'value': _dec_imei(v[:16])}]
if qual == 0x03 and len(v) >= 14:
yr = 2000 + int(v[0:2]) if int(v[0:2]) < 70 else 1900 + int(v[0:2])
mo, dy = int(v[2:4]), int(v[4:6])
hh, mm, ss = int(v[6:8]), int(v[8:10]), int(v[10:12])
tz = int(v[12:14], 16)
tz_sign = '-' if tz & 0x80 else '+'
tz_q = (tz & 0x3F) or 0
return [{'label': 'Date', 'value': '%04d-%02d-%02d' % (yr, mo, dy)},
{'label': 'Time', 'value': '%02d:%02d:%02d' % (hh, mm, ss)},
{'label': 'TZ offset', 'value': '%s%02d:%02d' % (tz_sign, tz_q // 4, (tz_q % 4) * 15)}]
# Date-Time and Time zone (TS 102 223 8.39): TP-SCTS coding
# (TS 123 040 9.2.3.11) - swapped semi-octet BCD digits, the
# time zone sign in bit 0x08 of the last byte, 'FF' unknown.
b = bytes.fromhex(v[:14])
y = _bcd_swap(b[0])
yr = 2000 + y if y < 70 else 1900 + y
out = [{'label': 'Date',
'value': '%04d-%02d-%02d' % (yr, _bcd_swap(b[1]), _bcd_swap(b[2]))},
{'label': 'Time',
'value': '%02d:%02d:%02d' % (_bcd_swap(b[3]), _bcd_swap(b[4]), _bcd_swap(b[5]))}]
if b[6] == 0xFF:
out.append({'label': 'TZ offset', 'value': 'unknown'})
else:
q = (b[6] & 0x07) * 10 + (b[6] >> 4)
out.append({'label': 'TZ offset',
'value': '%s%02d:%02d' % ('-' if b[6] & 0x08 else '+',
q // 4, (q % 4) * 15)})
return out
if qual == 0x04 and len(v) >= 4:
try:
lang = bytes.fromhex(v[:4]).decode('ascii')
@@ -3533,21 +3543,39 @@ def _scp81_bip_control(body):
'listener': _bip_listener_status()}
def _build_tr(scc, cmd_num, cmd_type, dev_src, dev_dst, cmd_qual):
"""Build the TERMINAL RESPONSE TLV payload for a fetched command
(includes PLI dictionary data for PROVIDE LOCAL INFORMATION)."""
if cmd_type == 0x03:
return bytes([0x81, 0x03, cmd_num, cmd_type, 0x00,
0x82, 0x02, dev_dst, dev_src,
0x84, 0x02, 0x01, _POLL_INTERVAL,
0x03, 0x01, 0x00])
def _pli_data_hex(cmd_qual, dt=None):
"""Data object(s) for a PROVIDE LOCAL INFORMATION TERMINAL RESPONSE, as
hex - or '' when there is nothing to send.
The TR Config dictionary entry (if any) wins. Otherwise the date/time
qualifier is answered with the current date and time from the host clock
(TS 102 223 6.4.15: "The terminal shall return the current date and time
as set by the user"), coded as the Date-Time and Time zone object (8.39).
`dt` is a test seam, the clock is read live otherwise."""
val = str(_PLI_DATA.get(cmd_qual, '') or '').strip()
if val:
return val
if cmd_qual == 0x03:
return '2607' + _encode_scts(dt).hex().upper()
return ''
def _build_tr(scc, cmd_num, cmd_type, dev_src, dev_dst, cmd_qual, dt=None):
"""Build the TERMINAL RESPONSE TLV payload for a fetched command.
The object order follows TS 102 223 6.8.0: command details, device
identities, Result, then the command-specific data objects (the echoed
Duration for POLL INTERVAL, the PLI data for PROVIDE LOCAL INFORMATION)."""
base = bytes([0x81, 0x03, cmd_num, cmd_type, 0x00,
0x82, 0x02, dev_dst, dev_src])
if cmd_type == 0x26 and cmd_qual is not None:
pli_hex = _PLI_DATA.get(cmd_qual, '')
0x82, 0x02, dev_dst, dev_src,
0x03, 0x01, 0x00])
if cmd_type == 0x03:
base += bytes([0x84, 0x02, 0x01, _POLL_INTERVAL])
elif cmd_type == 0x26 and cmd_qual is not None:
pli_hex = _pli_data_hex(cmd_qual, dt)
if pli_hex:
base += bytes.fromhex(pli_hex)
return base + bytes([0x03, 0x01, 0x00])
return base