Files
simple/tests/test_read_selected.py
T
catarrh 0231df905c equip/init: read the selected EF directly, bound the startup drain
pySim's scc.read_binary/read_record call select_path(ef) first, so the
ICCID, network-state, EF.ARR and EF.PBR readers - which had already made a
parent-scoped selection and hold its FCP - sent a second SELECT per file
and per record.  _read_selected_ef() issues READ BINARY (chunked at
max_cmd_len from the FCP file size) / READ RECORD (b2<rec>04<len> at the
FCP record length) directly; the pySim helpers stay as the fallback when
the FCP lacks the value.

The startup TERMINAL PROFILE drain now breaks on the chain's idle SW
instead of polling STATUS once more.

Measured on the last startup: ~3.4 s traced init (netstate/ARR/PBR 271
APDUs / 1.26 s incl. 169 SELECTs; the card's own TP processing 1.58 s);
the change removes ~0.7-0.8 s of the read phase without touching any data
or the TP.

v3.38.1; tests: tests/test_read_selected.py (direct reads, chunking, the
fallback and the drain source pin) and the ARR/PBR/ICCID/netstate fakes.
1067 Python + 1075 frontend.  sw cache simple-v482.
2026-10-24 18:54:31 +03:00

94 lines
3.1 KiB
Python

"""The direct read of an already-selected EF (v3.38.1).
pySim's ``scc.read_binary``/``scc.read_record`` select the file first; the
equip/init readers have already made a parent-scoped selection and hold its
FCP, so that second SELECT is pure overhead (one per file, one per record).
These tests pin the direct READ BINARY/READ RECORD form, the chunking and the
fallback when the FCP lacks the size/record length.
"""
import pathlib
import unittest
from pysim_simple_server import server as S
class FakeScc:
cla_byte = '00'
max_cmd_len = 255
def __init__(self, data='AABB'):
self.sent = []
self.data = data
def send_apdu_checksw(self, pdu):
self.sent.append(pdu)
return self.data, '9000'
class FakeLchan:
def __init__(self, size=2, rec_len=2, data='AABB'):
self.scc = FakeScc(data)
self.size = size
self.rec_len = rec_len
def selected_file_size(self):
return self.size
def selected_file_record_len(self):
return self.rec_len
def read_binary(self, *args):
raise AssertionError('pySim read_binary (re-select) used')
def read_record(self, *args):
raise AssertionError('pySim read_record (re-select) used')
class ReadSelectedTests(unittest.TestCase):
def test_a_transparent_read_is_direct(self):
lchan = FakeLchan(size=2)
self.assertEqual(S._read_selected_ef(lchan, 'transparent'),
('AABB', '9000'))
self.assertEqual(lchan.scc.sent, ['00b0000002'])
def test_a_transparent_file_is_chunked_at_max_cmd_len(self):
lchan = FakeLchan(size=300)
S._read_selected_ef(lchan, 'transparent')
# 255 bytes at offset 0, then 45 bytes at offset 0x00ff
self.assertEqual(lchan.scc.sent, ['00b00000ff', '00b000ff2d'])
def test_an_empty_file_reads_nothing(self):
lchan = FakeLchan(size=0)
self.assertEqual(S._read_selected_ef(lchan, 'transparent'),
('', '9000'))
self.assertEqual(lchan.scc.sent, [])
def test_a_record_read_is_direct(self):
lchan = FakeLchan(rec_len=6)
S._read_selected_ef(lchan, 'record', 3)
self.assertEqual(lchan.scc.sent, ['00b2030406'])
def test_a_missing_fcp_falls_back_to_the_pysim_helpers(self):
lchan = FakeLchan(size=None, rec_len=None)
lchan.read_binary = lambda *a: ('CC', '9000')
lchan.read_record = lambda n: ('DD', '9000')
self.assertEqual(S._read_selected_ef(lchan, 'transparent'),
('CC', '9000'))
self.assertEqual(S._read_selected_ef(lchan, 'record', 1),
('DD', '9000'))
class StartupDrainPin(unittest.TestCase):
"""The startup drain must not poll STATUS again after the chain already
returned an idle SW (v3.38.1)."""
def test_the_drain_uses_the_chain_result(self):
src = (pathlib.Path(S.__file__).parent / '__main__.py').read_text()
self.assertIn('chain_sw = _handle_proactive_chain(scc, st_sw)', src)
self.assertIn("if chain_sw and not chain_sw.startswith('91'):", src)
if __name__ == '__main__':