catarrh bb13ed45f8 net: initialize the monitor in the startup equip path (v2.7.1)
The startup init (server booted with the card already in the reader) equips
the card and reads the ICCID itself, but never created server.net_state -
only /api/command equip and the auto-equip worker did.  With a card present
at boot the monitor stayed empty, net-sim responses carried net_state: null
and the panel only started updating after pressing Refresh (which lazily
created the state).  Fix:

- factor _netstate_read(app) / _netstate_install() / _netstate_init() in
  server.py; _apply_equipped_card uses _netstate_init()
- __main__ startup: read the monitored EFs in the same CAT-free window as
  the ICCID and install the state once the server object exists
- _netstate_ensure() lazily initializes the state in the net-sim/event hooks
  so any equip path predating the monitor cannot leave it dead
- netSimRun falls back to netStateFetch() when a response has no net_state
- tests: tests/test_netstate_server.py (candidate order, record vs
  transparent, absent files, install, ensure); SW cache simple-v204
2026-09-20 13:12:00 +03:00

278 lines
14 KiB
Python

import argparse
import logging
import os
import sys
import time
import traceback
from http.server import HTTPServer
from pySim.card_handler import CardHandler
from pySim.commands import SimCardCommands
from pySim.exceptions import NoCardError
from pySim.log import PySimLogger
from pySim.cards import UiccCardBase
from .shell import load_pysim_app
from . import fastinit
from .server import PysimHandler, StderrApduTracer, _LoggingApduTracer, VERSION, _send_terminal_profile, _DefaultProactiveHandler, _handle_proactive_chain, _send_status, _init_proactive_session, _timing_on, _tlog, _set_menu_timeout, start_card_monitor, set_auto_equip, _read_iccid, _netstate_read, _netstate_install, _LineFilter
_server_start = 0
def _log_stdout(msg):
elapsed = time.time() - _server_start
os.write(1, ('[%8.3f] %s\n' % (elapsed, msg)).encode())
def _default_web_dir():
# <repo>/frontend, whether run from source or an editable install.
return os.path.join(os.path.dirname(os.path.dirname(os.path.abspath(__file__))), 'frontend')
def _default_mcc_mnc_list():
# Workspace default: the CC-BY-SA operator list lives outside the repo
# (<workspace>/samples/mcc-mnc-list.json); clones can point elsewhere with
# --mcc-mnc-list and the endpoint reports available=false when missing.
repo = os.path.dirname(os.path.dirname(os.path.abspath(__file__)))
return os.path.normpath(os.path.join(repo, '..', 'samples', 'mcc-mnc-list.json'))
def main():
global _server_start
_server_start = time.time()
mod = load_pysim_app()
parser = mod.option_parser
parser.description = 'pysim-simple-server — HTTP API for pysim'
parser.add_argument('--http-host', default='127.0.0.1', help='Bind address (default: 127.0.0.1)')
parser.add_argument('--http-port', type=int, default=8080, help='Bind port (default: 8080)')
parser.add_argument('--web-dir', default=_default_web_dir(), metavar='PATH',
help='Directory with the SIMple PWA static files to serve (default: <repo>/frontend)')
parser.add_argument('--mcc-mnc-list', default=_default_mcc_mnc_list(), metavar='PATH',
help='Worldwide MCC/MNC operator list (JSON) for the network-simulation operator picker (default: <workspace>/samples/mcc-mnc-list.json)')
parser.add_argument('--log-requests', action='store_true', default=False, help='Log request/response payloads to stderr')
parser.add_argument('--sms-oa', default='12345', metavar='DIGITS',
help='TP-Originating-Address (SMSC number) for the SMS-DELIVER TPDU (default: 12345)')
parser.add_argument('--sms-sm-sc', default='12345678912', metavar='DIGITS',
help='SM-SC address for SMS-SUBMIT routing in PoR-in-submit mode (default: 12345678912)')
parser.add_argument('--terminal-profile',
default='FFFFFFFF7F9F00DFFF03021FE2000000C3FB000704117800710100000038428003',
metavar='HEX',
help='TERMINAL PROFILE payload (default: the 33-byte profile of a real BIP-capable handset - the live card only starts HTTP OTA when BIP events/commands are advertised)')
parser.add_argument('--poll-interval', type=int, default=30, metavar='SECS',
help='Idle interval before automatic STATUS polling (1-255 seconds, default: 30). Disable with --poll-interval 0')
parser.add_argument('--no-card-init', action='store_true', default=False,
help='Skip pysim card initialization (preserve CAT session — no file manager)')
parser.add_argument('--timing', action='store_true', default=False,
help='Log phase durations, card resets and APDU counters with elapsed timestamps')
parser.add_argument('--fast-init', action='store_true', help=argparse.SUPPRESS)
parser.add_argument('--full-pysim-init', action='store_true', default=False,
help="Use pysim's stock init_card/equip (multiple physical card resets) instead of the default reset-free fast init")
parser.add_argument('--menu-timeout', type=int, default=60, metavar='SECS',
help='Auto-send a timeout TERMINAL RESPONSE if a paused STK command is not answered (default: 60, 0 disables)')
parser.add_argument('--no-auto-equip', action='store_true', default=False,
help='Do not automatically initialize a card right after it is inserted (default: auto-equip on)')
opts = parser.parse_args()
opts.skip_card_init = opts.no_card_init
opts.fast_init = not opts.full_pysim_init
if opts.timing:
_timing_on()
if opts.menu_timeout is not None:
_set_menu_timeout(opts.menu_timeout)
set_auto_equip(not opts.no_auto_equip and not opts.skip_card_init)
sl = None
scc = None
card = None
rs = None
sim_menu = None
event_list = None
# Auto-detect PC/SC reader if none was explicitly specified.
# Handles late pcscd startup and USB enumeration delays.
if opts.pcsc_dev is None and opts.pcsc_regex is None:
try:
from smartcard.System import readers
for attempt in range(3):
r = readers()
if r:
sys.stderr.write('INIT: PC/SC reader detected: %s\n' % r[0])
opts.pcsc_dev = 0
break
if attempt < 2:
sys.stderr.write('INIT: no PC/SC readers found, retrying in 2s...\n')
time.sleep(2)
except Exception:
pass # smartcard module not available or pcscd unreachable
try:
kwargs = {}
if opts.apdu_trace:
kwargs['apdu_tracer'] = _LoggingApduTracer()
t_phase = time.time()
sl = mod.init_reader(opts, **kwargs)
_tlog('init_reader: %.0fms' % ((time.time() - t_phase) * 1000))
scc = SimCardCommands(sl)
scc.cat_cla = '80' # UICC CLA default; overridden for SIM after init_card
scc._tp.proactive_handler = _DefaultProactiveHandler()
t_phase = time.time()
if opts.fast_init:
try:
rs, card = fastinit.init_card_fast(sl, opts.skip_card_init, wait=True)
except NoCardError:
# Normal cardless start: there was no card in the reader (the
# 3s wait timed out). The presence monitor auto-equips once a
# card appears; nothing to recover, no traceback.
sys.stderr.write('INIT: no card in the reader — server ready; insert a card or press Equip\n')
except Exception:
print("Warning: fast card initialization failed, falling back to pysim init:", file=sys.stderr)
traceback.print_exc()
try:
rs, card = mod.init_card(sl, opts.skip_card_init)
except NoCardError:
# The fallback retried the cardless wait; still a normal
# cardless start, not an initialization failure.
sys.stderr.write('INIT: no card in the reader — server ready; insert a card or press Equip\n')
else:
try:
sl.wait_for_card(3)
rs, card = mod.init_card(sl, opts.skip_card_init)
except NoCardError:
sys.stderr.write('INIT: no card in the reader — server ready; insert a card or press Equip\n')
_tlog('card_init: %.0fms' % ((time.time() - t_phase) * 1000))
if card is not None:
scc.cat_cla = '80' if isinstance(card, UiccCardBase) else 'a0'
except Exception:
print("Warning: reader/card initialization failed:", file=sys.stderr)
traceback.print_exc()
ch = CardHandler(sl) if sl else None
t_phase = time.time()
try:
if card is not None:
app = mod.PysimApp(verbose=opts.verbose, card=card, rs=rs, sl=sl, ch=ch)
else:
# Cardless start: pySim logs 'Waiting for card...' (its own retry
# path) and pySim-shell prints 'pySim-shell not equipped!'; we
# report both cases with our own single line above. A PysimApp
# without a card would also retry the cardless wait, so install
# the filter before constructing it and drop the two internals.
saved_stdout = sys.stdout
sys.stdout = _LineFilter(saved_stdout, ('Waiting for card...', 'pySim-shell not equipped!'))
try:
app = mod.PysimApp(verbose=opts.verbose, card=None, rs=None, sl=sl, ch=ch)
finally:
sys.stdout = saved_stdout
except Exception:
print("Warning: PysimApp creation failed:", file=sys.stderr)
traceback.print_exc()
app = None
_tlog('pysim_app: %.0fms' % ((time.time() - t_phase) * 1000))
if app is not None and opts.fast_init:
fastinit.install(app)
iccid = None
netstate_files = None
if scc and card is not None and hasattr(scc, '_tp'):
scc._tp.apdu_tracer = _LoggingApduTracer()
try:
_init_proactive_session()
# Read EF.ICCID before the TERMINAL PROFILE starts the CAT session
# (the PWA auto-selects the matching card preset from it).
iccid = _read_iccid(app)
if iccid:
sys.stderr.write('INIT: ICCID %s\n' % iccid)
# Network state monitor: read the network-related EFs in the
# same CAT-free window (skipped without a readable ICCID).
try:
netstate_files = _netstate_read(app)
except Exception:
netstate_files = None
t_phase = time.time()
sys.stderr.write('INIT: sending TERMINAL PROFILE %s (CLA=%s)\n' % (opts.terminal_profile, scc.cat_cla))
sm, el = _send_terminal_profile(scc, opts.terminal_profile)
sys.stderr.write('INIT: TP done, menu=%s events=%s\n' % ('yes' if sm else 'no', 'yes' if el else 'no'))
sim_menu = sm or sim_menu
event_list = el or event_list
for _ in range(3):
st_data, st_sw = _send_status(scc)
sys.stderr.write('INIT: drain STATUS -> %s\n' % st_sw)
if not st_sw.startswith('91'):
break
_handle_proactive_chain(scc, st_sw)
_tlog('terminal_profile_drain: %.0fms' % ((time.time() - t_phase) * 1000))
except Exception:
traceback.print_exc(file=sys.stderr)
if app is not None and opts.apdu_trace:
# PysimApp.__init__ routes PySimLogger through app.poutput() (app.stdout)
# and drops the root level to INFO. Re-route pysim's own APDU trace logging
# directly to fd 1 so it survives the app.stdout/StringIO redirection in the
# HTTP handlers and the INFO level suppression.
PySimLogger.setup(print_callback=_log_stdout)
PySimLogger.set_level(logging.DEBUG)
# PysimApp.__init__ and every `equip` wipe the transport apdu_tracer
# (_onchange_apdu_trace sets it to None). Re-attach our tracer and make
# sure it stays attached across equip/re-equip.
tracer = _LoggingApduTracer()
def _reattach_tracer():
if app.card:
app.card._scc._tp.apdu_tracer = tracer
_reattach_tracer()
orig_onchange = app._onchange_apdu_trace
def _onchange_apdu_trace(param_name, old, new):
orig_onchange(param_name, old, new)
_reattach_tracer()
app._onchange_apdu_trace = _onchange_apdu_trace
server = HTTPServer((opts.http_host, opts.http_port), PysimHandler)
server.sl = sl
server.scc = scc
server.card = card
server.rs = rs
server.app = app
server.sms_oa = opts.sms_oa
server.sms_sc = opts.sms_sm_sc
server.log_requests = opts.log_requests
server.terminal_profile = opts.terminal_profile
server.cli_terminal_profile = opts.terminal_profile
server.web_dir = opts.web_dir
server.mcc_mnc_path = opts.mcc_mnc_list
server.sim_menu = sim_menu
server.event_list = event_list
server.menu_active = False
server.stk_pending = None
server.card_present = card is not None
server.card_session = 1 if card is not None else 0
server.iccid = iccid
# Network state monitor: install the state read during the startup init
# (right after the ICCID, before the TERMINAL PROFILE). No readable
# ICCID means the card is considered unusable - give up.
try:
_netstate_install(server, netstate_files if iccid else None)
except Exception as e:
server.net_state = None
sys.stderr.write('INIT: network state failed: %s\n' % e)
server.equipping = False
# Set server reference for polling timer and mark the card session state
import pysim_simple_server.server
pysim_simple_server.server._server_ref = server
pysim_simple_server.server._CARD_CONNECTED = card is not None
if opts.poll_interval is not None:
pysim_simple_server.server._set_poll_interval(opts.poll_interval)
# Auto-enable polling if card initialized successfully (unless interval is 0)
if server.scc and server.card and opts.poll_interval != 0:
pysim_simple_server.server._poll_enable()
# Start presence monitoring only after the startup init: pyscard reports an
# already-present card as "added" on the first pass, and we must not
# auto-equip over a session we just initialized. If startup init failed,
# that event triggers auto-equip instead — the desired retry.
if sl is not None and getattr(sl, '_reader', None) is not None:
start_card_monitor(str(sl._reader))
print("─" * 70)
print(" pysim-simple-server v%s listening on http://%s:%s" % (VERSION, opts.http_host, opts.http_port))
print(" Open http://%s:%s in your browser for the SIMple UI (served by this server)."
% (opts.http_host, opts.http_port))
print("─" * 70)
try:
server.serve_forever()
except KeyboardInterrupt:
print("\nShutting down...")
server.shutdown()
if __name__ == '__main__':
main()