- a record whose FCP understates the layout (the reported case: record_len 2 while the READ RECORD carried P3=0x2C and returned 44 bytes) had its rows cut to two cells by the v2.7.3 length rule, hiding 42 newly-observed bytes while the summary still counted them - the filler now stops at the known length only while the data fits inside it; beyond that — and when the length is unknown or absent — the row ends at the data, so nothing observed is ever hidden and no bytes are invented - verified on the live payload (session 55, 5f3a/4f09 change 0): before = 2 cells, both changed; after = 16+16+12 cells with 2 changed and 42 newly observed, matching the summary line - tests: the regression case (a 2-byte record_len with a 44-byte read) and the unknown-length case, whose row now ends at the data; 527 Python + 76 Node tests - PWA_VERSION/pyproject/version.py 2.7.5, SW cache simtrace-analyser-v85
22 lines
664 B
TOML
22 lines
664 B
TOML
[build-system]
|
|
requires = ["setuptools>=64"]
|
|
build-backend = "setuptools.backends._legacy:_Backend"
|
|
|
|
[project]
|
|
name = "simtrace-analyser"
|
|
version = "2.7.5"
|
|
description = "SIMtrace Analyser — APDU trace analyser for GSMTAP/PCAP captures (bundles the simtrace2-pysniff utility)"
|
|
readme = {file = "README.md", content-type = "text/markdown"}
|
|
license = {text = "GPL-2.0-or-later"}
|
|
requires-python = ">=3.9"
|
|
dependencies = [
|
|
"pyusb>=1.2",
|
|
]
|
|
|
|
[project.scripts]
|
|
simtrace-analyser-server = "simtrace_analyser.__main__:main"
|
|
simtrace2-pysniff = "simtrace2_pysniff.__main__:main"
|
|
|
|
[tool.setuptools.packages.find]
|
|
include = ["simtrace_analyser*", "simtrace2_pysniff*"]
|