osmo_apdu_segment_in() doesn't have the context of the previous APDU,
for nearly all calls this is fine, except for GP GET DATA, which can be
a case 2 or case 4 APDU.
GP GET DATA defines the Le field as 0x00 which is used by osmo_apdu_segment_in
to detect if it is a case 2 or case 4.
However a card can respond with the SW 6cXX, which means the previous
command must be resend with a Le field XX, which got misinterpreted by
the osmo_apdu_segment_in() as a case 4 resulting in a timeout waiting for
more data.
Modem <-> Card
81cadf2000 ->
<- 6c0b
81cadf200b ->
-- Simtrace waits for more data because it wrongly decodes it as APDU case 4
instead of case 2.
Related: SYS#8147
Change-Id: Ie238662e7e6a10dd4283ede0c8d8d73bc375c247
8 lines
184 B
Plaintext
8 lines
184 B
Plaintext
Testing get_data_c2_ca
|
|
Testing get_data_c2_cb
|
|
Testing get_data_c2_ca
|
|
Testing get_data_c2_cb
|
|
Testing GET DATA / 0xCA with SW 6Cxx
|
|
Testing GET DATA / 0xCB with SW 6Cxx
|
|