Files
sigrok_iso7816_stream/AGENTS.md
T
catarrh 250c09c9b7 v1.9.0: CLK rate in RST events; v1.9.1: T=0 NULL is not an SW1
v1.9.0 -- CLK frequency in RST events:
- RST events (sub_type 0x10) append the measured CLK frequency when known:
  [direction, level, flags, clk_hz_be32], flags bit 0 = rate present; the
  3-byte form is kept when the rate is not yet measured.  Value is
  samplerate / _samples_per_clock from the existing 16-edge measurement (PPS
  changes F/D, not the CLK rate).  VCC events unchanged.  Backward
  compatible (old consumers read the first two bytes only); consumers can
  compute data_rate = clk_hz x D / F from the ATR/PPS Fi/Di.
- Unit tests for the payload codec; README/README_RUS/AGENTS updated.

v1.9.1 -- T=0 NULL is not an SW1:
- The 'scan for SW1' loops accepted any 0x6X byte, including the NULL
  procedure byte 0x60 (card busy), so 'NULL + real SW1' was mis-framed as
  the status word: the phone traces' SELECT MF came out as ...3f00 6061 —
  real SW1 0x61 eaten as SW2, real SW2 0x29 left on the wire and discarded
  as a suspicious CLA (desync cascade).
- plausible_sw() now accepts 0x61-0x6F and 0x90-0x9F only, per
  ISO 7816-3:2006 10.3.3 Table 11 ('6X' or '9X', EXCEPT '60'; ISO 7816-4
  enforces '60' as an invalid SW1) and UICC_SPECS.md 1.8.  All seven
  SW1-detection sites use plausible_sw(); NULLs met while scanning are
  logged as rate-limited wait extensions (_note_pre_sw) instead of
  suspicious bytes.
- tools/vs_reader.py::_plausible_sw() mirrors the fix; regression vector
  for the 00a40004023f006061 artifact.

Validation: 74/74 unit tests; baseline regenerated and IDENTICAL (the SW
fix is count-neutral -- only the SW bytes change); all 9 example pcaps
regenerated -- vs_reader OK, zero APDUs ending in 60 61, SELECT MF now
61 29 / 61 25.
2026-09-19 00:55:33 +03:00

52 KiB
Raw Blame History

AGENTS.md

Policy: decoder changes must be validated against ALL example traces

Every change to pd.py must be followed by running the full test suite:

  1. Clear bytecode cache first - stale .pyc files cause false results:

    find . -name "__pycache__" -type d -exec rm -rf {} +
    find . -name "*.pyc" -delete 2>/dev/null
    
  2. Run all traces in mid-session mode (the decoder always runs this way; captures all APDUs, including cold-boot ATRs):

    # Run decoder for each trace
    for trace in test_8_raw16 test_7_raw16 xiaomi_phone_sample \
                samsung_phone_sample \
                xiaomi_mi_a1_coldboot_sample 4gmodem_coldboot_sample \
                samsung_A55_coldboot_new_cable samsung_A55_coldboot_new_cable_sim2 \
                samsung_S21p_coldboot_new_cable samsung_S21p_coldboot_new_cable_sim2; do
        # Run sigrok-cli and vs_reader as shown below
        # Capture APDUs, GARBAGE count, and RESULT
    done
    
  3. Acceptance criteria (must ALL pass):

    • test_8 mid-session: 56 APDUs, 28/37 reader exchanges (9 pre-capture), 0 GARBAGE, RESULT: OK
    • test_7 mid-session: 65 APDUs, 37/37 reader exchanges, 0 GARBAGE, RESULT: OK
    • All smoke-test traces: >0 APDUs in mid-session mode
    • No regressions: GARBAGE count must not increase, no new BAD_FCS/payload mismatches
    • Unit tests: 30/30 pass (python3 tests/test_gsmtap.py -v)

Important: CLK signal behavior matters

  • Constant CLK (test_7, test_8): Card reader keeps CLK running continuously

    • Decoder can reliably sample DATA on each CLK edge
    • Cold-boot re-arm handles warm resets
  • Gated CLK (phone traces): Phone stops CLK when idle, restarts before next APDU set

    • Decoder must handle CLK gaps and restart properly
    • ETU auto-detection from DATA edges is critical
    • This is the decoder's primary use case
  • Cold boot captured pre-power-up (*_coldboot_sample.sr): VCC/RST are LOW at t=0, capture spans the power-on (~17 s at 16 MHz), and the card emits its ATR once RST deasserts

    • Decoder must arm the ATR hunt when RST is still low at capture start (see "Cold-boot re-arm") and not lock an ETU from pre-ATR power-up traffic
    • It must decode the ATR 3b9f96801f...001e
    • rst_detect=true, vcc_detect=true for these fixtures
# --- test_8 ---
sigrok-cli -i examples/test_8_raw16.sr \
  -P iso7816:clk=CLK:data=DATA:rst=RST:vcc=VCC:clock_option=native:rst_detect=true:gsmtap_enable=false:pcap_file=/tmp/out.pcap \
  -A iso7816 >/dev/null
python3 tools/vs_reader.py examples/test_8_reader.log /tmp/out.pcap

# --- test_7 ---
sigrok-cli -i examples/test_7_raw16.sr \
  -P iso7816:clk=CLK:data=DATA:rst=RST:vcc=VCC:clock_option=native:rst_detect=true:gsmtap_enable=false:pcap_file=/tmp/out.pcap \
  -A iso7816 >/dev/null
python3 tools/vs_reader.py examples/test_7_reader.log /tmp/out.pcap

# --- xiaomi phone (gated CLK) ---
sigrok-cli -i examples/xiaomi_phone_sample.sr \
  -P iso7816:clk=CLK:data=DATA:rst=RST:clock_option=native:protocol=T=0:gsmtap_enable=false:pcap_file=/tmp/out.pcap \
  -A iso7816 >/dev/null

# --- samsung phone 1 (gated CLK, non-default F/D) ---
sigrok-cli -i examples/samsung_phone_sample.sr \
  -P iso7816:clk=CLK:data=DATA:rst=RST:vcc=VCC:clock_option=native:protocol=T=0:gsmtap_enable=false:pcap_file=/tmp/out.pcap \
  -A iso7816 >/dev/null

# --- xiaomi_mi_a1_coldboot (starts pre-power-up) ---
#     rst_detect/vcc_detect=true are required for these fixtures.
sigrok-cli -i examples/xiaomi_mi_a1_coldboot_sample.sr \
  -P iso7816:clk=CLK:data=DATA:rst=RST:vcc=VCC:clock_option=native:protocol=T=0:rst_detect=true:vcc_detect=true:gsmtap_enable=false:pcap_file=/tmp/out.pcap \
  -A iso7816 >/dev/null

# --- 4gmodem_coldboot ---
sigrok-cli -i examples/4gmodem_coldboot_sample.sr \
  -P iso7816:clk=CLK:data=DATA:rst=RST:vcc=VCC:clock_option=native:protocol=T=0:rst_detect=true:vcc_detect=true:gsmtap_enable=false:pcap_file=/tmp/out.pcap \
  -A iso7816 >/dev/null

# --- unit tests ---
python3 tests/test_gsmtap.py -v

Always clear the Python bytecode cache before testing — stale .pyc files can cause the decoder to use old code, producing false results:

find . -name "__pycache__" -type d -exec rm -rf {} +

The acceptance criteria are:

The decoder is NOT considered fully functional until ALL of these criteria are met.

Ground truth

test_7_reader.log and test_8_reader.log are trusted, complete APDU logs captured by the PC/SC reader SDK during the same recording session as the sigrok trace. They contain every command the reader sent and every response the card returned. They are the authoritative reference — the decoder output must match them.

Success criteria (all must pass)

  1. test_8 and test_7 (reader-log traces):

    • Every reader exchange must appear in the decoder output. For test_8: 28/37 reader exchanges are present in the pcap (9 missing because they occurred before the capture started — a trace-level limitation, not a decoder bug). For test_7: all 37/37 are present after the v1.1.10 deglitch fix (previously only 10/37 due to ATR resets fragmenting the session).
    • 0 garbage APDUs in mid-session mode.
    • RESULT: OK from vs_reader.py.
  2. All traces (including smoke-test):

    • >0 APDUs in mid-session mode for smoke-test traces.
    • No increase in CHKSUM ERROR, BAD_FCS, payload mismatches, or suspicious CLA counts.
  3. Every trace must be tested (the decoder always runs mid-session — it captures all APDUs, including cold-boot ATRs).

Known issues (must be fixed to meet criteria)

T=0 framing produces incorrect APDUs. The decoder's output now matches the reader log for all reader exchanges:

  • test_8: 28/37 reader exchanges are byte-identical in the pcap (9 missing because they occurred before the capture started), plus 17 extra CAT/proactive commands and 11 valid retries, total 56 APDUs, 0 garbage.
  • test_7: All 37/37 reader exchanges are byte-identical in the pcap, plus 17 CAT/proactive commands, 8 ATRs, and 11 valid retries, total 65 APDUs, 0 garbage.

Both traces show 0 garbage APDUs, 0 payload mismatches, and RESULT: OK.

Root cause: _edge_read is initialized to True and never set to False, so the edge-read T=0 procedure loop (lines 1808–1895) always executes — the ATR-based procedure loop (lines 1898–1941) is dead code. The edge-read path had two bugs:

  1. NULLs treated as command data (FIXED). The first post-header byte was checked for ACK; if it was NULL (0x60), it entered the case-3/4 branch and got appended as command data. Fixed by skipping NULLs before the ACK check.

  2. "Read until SW" truncates GET RESPONSE (FIXED). The ACK handler read until it saw a byte in 0x6x/0x9x range, but FCP tag 0x62 matched this pattern, truncating GET RESPONSE to 1-2 bytes. Fixed by using P3-bounded reads (read exactly P3 bytes then SW1 SW2) for case-2 commands where P3 = Le.

CLA validation note

All example traces (test_7, test_8, xiaomi, samsung) contain only CLA 0x00 (interindustry) and 0x8x (USIM/CAT, mostly 0x80 with occasional 0x81 for logical channel 1). The decoder must not mandate specific CLA values — other CLA values (e.g. 0x04, 0x08, 0x84, 0xA0, 0xB0) are valid per ISO 7816-4 / 3GPP and must be accepted. However, during test runs against the example traces, any CLA value outside 0x00-0x0F and 0x80-0x8F is an error flag indicating the decoder mis-framed the byte stream.

ISO 7816 APDU validation (enforced from v1.1.7)

The decoder validates every reassembled T=0 APDU with validate_t0_apdu() before emitting it. Invalid APDUs are still packed into gsmtap but are flagged with GSMTAP_FLAG_BAD_FCS.

Validation is purely structural (no content scanning of command/response data), so the false-positive rate is very low. The checks are:

  1. Length is at least 7 bytes (header + SW) and at most MAX_TPDU_LEN (271).
  2. CLA byte is in the recognized set (0x00, 0x04, 0x08, 0x80, 0x84, 0xA0, 0xB0).
  3. INS byte is plausible: not 0x00, not in 0x6x/0x9x (status-word collision), and the least-significant bit is 0.
  4. The penultimate byte (SW1) is in 0x61–0x6F or 0x90–0x9F. 0x60 is explicitly invalid: it is the T=0 NULL procedure byte (ISO 7816-3 §10.3.3 Table 11 marks SW1 as '6X' except '60'; ISO 7816-4 enforces '60' as an invalid SW1), so a "NULL + real SW1" pair must never be accepted as a status word.

The current validation deliberately does not enforce P3-based length constraints, because a card may reject a command and send the status word immediately even when P3 > 0.

v1.4.0: CONCAT detection (embedded exchanges, issue #1 gate)

A byte-drop mis-frame swallows several real T=0 exchanges into one structurally "valid" packet: each swallowed header survives verbatim in the data region, followed by its P3 data bytes and an interior status word. Such packets pass validate_t0_apdu() but produce wrong APDUs downstream. embedded_exchanges() (pd.py) scans the data region ([5, n-9]) for embedded complete exchanges:

  • header CLA INS P1 P2 P3 where INS ∈ EMBEDDED_INS (commands that actually occur on these cards: 12/14/20/44/70/88/A2/A4/B0/B2/B6/C0/C2/ CA/CB/D6/DC/F2) and P3 ≥ 1
  • CLA valid, or the phantom byte-drop artifact 0x01 (corrupt 0x00), with a one-byte prefix slip tolerated when byte 0x01 precedes a real header
  • SW1 accepted in a 3-byte slack window after the nominal data end (d1 = s + 5 + p3), from EMBEDDED_SW1 (real status bytes that are not also frequent data bytes), and the SW must be interior (sw < n-2, i.e. more exchange data must follow it)

On a hit the decoder flags the packet GSMTAP_FLAG_BAD_FCS and logs CONCAT APDU: <k> embedded exchange(s) at <offsets>; packet <hex>, so the gate works live and offline. The detector is precision-tuned against all 10 example traces: 0 hits on clean traces (test_8/test_7/4gmodem), and it flags every known corrupted family:

Trace APDUs CONCAT hits
test_8 56 0
test_7 65 0
xiaomi_phone 620 4
samsung_phone 924 5
xiaomi_mi_a1_coldboot 459 3
4gmodem_coldboot 327 0
A55_coldboot_new_cable 386 3
A55_coldboot_new_cable_sim2 375 2
S21p_coldboot_new_cable 380 3
S21p_coldboot_new_cable_sim2 356 2

The concat packets are BAD_FCS-flagged on the phone traces, so their BAD_FCS counts now equal the CONCAT counts (deliberate: those APDUs are genuinely desynced). vs_reader.py reports the same detector; capture_baseline.sh prints CONCAT APDU count: N per trace (grep of the CONCAT APDU: log line only, so one line per packet). Acceptance: test_8/test_7/4gmodem must stay 0; phone-trace counts must not increase.

v1.4.0: CONCAT gate — embedded-exchange detection (issue #1)

The decoder previously emitted byte-drop-mis-framed APDUs that swallowed several real exchanges into one "valid" packet (the Samsung/xiaomi "wrong APDU" family). Fragmentation is not representable in the assembled bytes, so this is fixed as a detection gate, not a reframe:

  • embedded_exchanges() scans the data region for embedded complete exchanges (see "v1.4.0: CONCAT detection" under APDU validation).
  • Hits are flagged GSMTAP_FLAG_BAD_FCS + logged CONCAT APDU: ....
  • vs_reader.py / capture_baseline.sh gain a CONCAT metric (packet counts match the log lines exactly).
  • Unit tests cover the tuned vectors (clean FCP/READ-RECORD/SELECT never hit; U1/U4/record-burst/xiaomi swallows are caught).
  • VERSION → 1.4.0. Baseline regenerated with the new CONCAT columns.

A proper reframing (re-splitting those packets and byte-dropping the mis-frame at the source) is the next decoder step; until then the gate makes the corruption visible in live and offline captures instead of silently producing wrong APDUs.

v1.6.0: ATR-hunt deadlock + idle-loop trap fixes

A live Samsung cold-boot capture that never emits a 372-rate ATR exposed two defects in the ATR hunt (state == 'FIND START'):

  1. Deadlock. RST low at start arms the hunt at the spec-default clock_skip=372 with bit_samples=None. The ETU-recovery routine _measure_etu() is only reachable from the DATA state, which the hunt can only enter after reading a valid TS=0x3B/0x3F (or a plausible CLA/INS header) at 372. A card already running at a non-default F/D (Samsung F=512/D=32 -> 16 CLK/bit) produces none, so the hunt reads idle 0xFF forever and never reaches the ETU measurement -- a circular dependency. This is why Samsung (non-default F/D) fails where default-F/D devices succeed: not clock rate, but F/D.

  2. Trap. The all-0xFF branch unconditionally reset _atr_hunt_count=0 and returned to FIND START, so the bounded fall-through to DATA was unreachable. With RST re-arm also resetting the counter, the hunt could spin forever.

Fixes:

  • Hunt-side ETU recovery. _recover_etu_in_hunt() runs _measure_etu()
    • _derive_clock_skip_from_etu() from the hunt after the default-rate hunt has already failed a few rounds, so a fast device is read at its true rate. It reuses the DATA-path _confirm_etu() validation, so a noise-locked ETU self-clears after 2 parity failures. No-op for normal ATRs (parsed on hunt 1).
  • Bounded escape. _atr_hunt_failure_action(byte) (pure, unit-tested) returns recover / retry / resume_data. ETU recovery every 2 failed rounds up to 3 times; then a hard bound (_atr_fail_total >= 12) or the all-0xFF idle cap (3) falls through to the existing "resuming DATA without synthetic ATR" path (clearing bit_samples so the DATA path re-measures).
  • Persistent counters. _atr_fail_total, _hunt_etu_attempts, _atr_idle_resets are reset only on a successful ATR parse, not on RST re-arm -- otherwise a phone that power-cycles RST while never sending a valid ATR would starve the escape. Constants: ATR_HUNT_ETU_ATTEMPTS=3, ATR_HUNT_IDLE_RESETS=3, ATR_HUNT_FAIL_LIMIT=12.

Verification: no regression on the full trace suite (test_8 56/0/OK, test_7 65/0/OK, xiaomi 640, xiaomi_cold 473, 4gmodem 327, A55 407/395, S21p 399/375, target S21p_coldboot 369, all RESULT: OK, 0 CONCAT); 54/54 unit tests (7 new hunt-escape regression tests). VERSION -> 1.6.0.

Known limitation: no on-disk fixture reproduces the exact live failure (all real captures contain a 372 ATR), so end-to-end proof needs a re-captured .sr from the failing phone; the unit tests cover the loop-escape logic.

v1.9.1: T=0 NULL is not an SW1 (fixes bogus "60 61" APDU endings)

The "scan for SW1" loops accepted any byte with high nibble 0x6 as a status word, including the T=0 NULL procedure byte 0x60 (card busy / waiting-time extension). A card that holds the terminal with NULLs while busy was therefore mis-framed: on the phone/cold-boot traces the SELECT MF wire flow is 00 a4 00 04 02 → ACK a4 → command data 3f 00 → ~1.4 s of NULL 60 → real SW 61 29. The decoder took 60 as SW1 and the real 0x61 as SW2, emitting …3f00 6061 and leaving the real SW2 (0x29) on the wire, where it was discarded as a suspicious CLA — and the bogus packet even passed validate_t0_apdu() because plausible_sw() accepted 0x60.

  • plausible_sw() now accepts 0x61–0x6F and 0x90–0x9F only. Authority: ISO 7816-3:2006 §10.3.3 Table 11 — "If the value is '6X' or '9X', except for '60', it is a SW1 byte"; the note adds that ISO 7816-4 enforces '60' as an invalid SW1. (UICC_SPECS.md §1.8 classes: normal '9000'/'61XX'; warning '62XX'/'63XX'; execution error '64XX'–'66XX'; checking error '67XX'–'6FXX'.)
  • Every SW1-detection site now uses plausible_sw(): the edge ACK scan, the P3=0 direct-SW check and response scan, the case-4 response scan, the case-3 SW1 check, the unexpected-byte scan, and the ATR path.
  • NULLs met while scanning for the status word are logged as rate-limited wait extensions via the new _note_pre_sw() (cards emit them in bursts, so they must not flood the log or raise warnings); other non-SW bytes keep their call-site reason.
  • tools/vs_reader.py::_plausible_sw() mirrors the fix.
  • Tests: plausible_sw vectors updated (0x60 now rejected; accepts start at 0x61), plus a regression vector for the 00 a4 00 04 02 3f 00 60 61 artifact (invalid SW1 / desynced).

The fix is count-neutral (the same bytes are consumed; only the SW bytes change), so tests/baseline.txt differs only by the version line and the new test listing. 74/74 unit tests. VERSION -> 1.9.1.

v1.9.0: CLK frequency in RST events

RST line events (sub_type 0x10) now append the measured CLK frequency when it is known: [direction, level, flags, clk_hz_be32], with flags bit 0 (LINE_EVENT_FLAG_CLK_HZ) set and the frequency as a big-endian uint32 in Hz (7-byte payload). An unknown rate keeps the 3-byte payload, so consumers that read only the first two bytes (e.g. pysniff's decode_line_event) are unaffected. The value is the existing 16-edge average (samplerate / _samples_per_clock, see _measure_clock_period); PPS changes F/D, not the CLK rate, so one measurement per session is enough. VCC events (0x11) are unchanged. Purpose: consumers can compute the actual data rate as clk_hz × D / F from the Fi/Di negotiated in the ATR/PPS. Ordering: the RST deassert event usually precedes the ATR event (the 10 ms hysteresis lands mid-ATR for full ATRs), but a short ATR can invert that, so consumers take the rate from any RST event. Wire extension is backward compatible; 73/73 unit tests; baseline regenerated and IDENTICAL (it tracks no RST payload metrics). VERSION -> 1.9.0.

v1.8.0: PPS emitted as standard request + response packets

The PPS exchange was previously emitted as a single packet under sub_type 0x02 (GSMTAP_SIM_PPS_REQ) carrying the request + response bytes concatenated — a deviation from libosmocore's gsmtap.h. It is now split into the two standard subtypes: 0x02 (PPS_REQ, raw request bytes, span ss..es_req) and 0x03 (PPS_RSP, raw response bytes, span es_req..end). Wireshark now dissects both halves, and simtrace2-pysniff needs no change: its pcap importer already maps 0x03 to pps and _decode_pps() parses any 0xFF-leading frame (the response frame also starts with 0xFF). The PPS annotation and stderr log lines are unchanged. tests/baseline.txt regenerated — the only differences were the version line and the unit-test listing, no decode-metric changes. 68/68 unit tests. VERSION -> 1.8.0.

v1.7.1: accept EOFError as clean end-of-stream (newer libsigrokdecode)

Newer libsigrokdecode signals end-of-capture from wait() by raising EOFError("samples exhausted"); the 0.5.3 build on the Linux dev box instead returns None / raises SystemError, so this only showed up on Windows (a newer libsigrokdecode). The framework explicitly accepts EOFError out of decode() as normal termination (instance.c: "Termination with an EOFError exception is accepted"), but our decode() caught it in the generic except Exception handler, printing a traceback, logging DECODE ERROR, and resyncing -- retrying up to 50 times and flooding the log (looked like a crash) at the end of every capture.

  • decode() and the five except SystemError: raise guards now use except (SystemError, EOFError): raise, so the end-of-stream signal propagates and libsigrokdecode terminates cleanly. The critical guard is _measure_clock_period(), whose try wraps a wait() loop.
  • 2 new unit tests assert decode() re-raises EOFError and SystemError.
  • 67/67 unit tests. VERSION -> 1.7.1.

Deployment note: the Windows decoder is a git clone, so git pull there (and deleting __pycache__) picks this up; the EOF error cannot be reproduced against Linux 0.5.3.

v1.7.0: spurious end-of-decode hardening + start.sh session resilience

A live capture could end without Ctrl+C (the session simply stopped). The frontend symptom was a flood of sr: session: sr_session_stop: session was NULL, but the decoder also had latent paths that could end decode() early on an idle/busy live line. Fixed:

  1. _at_eof(). decode_step() treated samplenum == _last_sn as EOF, but a step can legitimately consume only queued bytes (_replay / peeked_byte) without advancing the stream -- e.g. the v1.5.0 invalid-INS re-frame. Such steps are now allowed up to 64 in a row; only a genuinely stuck stream with nothing queued ends the decode.
  2. _stall_check(track=False). The idle-LEVEL wait in wait_data_falling() returns immediately at the current sample whenever DATA is already idle -- normal on a live idle line, not EOF. Stall counting is now disabled for that wait (only pins is None means EOF); sample-stall detection is kept for the start-bit EDGE wait.
  3. resync_idle() null guard. It indexed pins[self.DATA_IDX] after wait() with no None check; at stream end that raised TypeError. Now sets _eof and returns.

Effect: samsung_phone_sample.sr had been halting at sample ~21.9M of 320M (1 APDU). It now decodes through sample ~293M to a true end: 939 APDUs, CHKSUM=176. The extra 6 CONCAT packets are real mis-framed STK bursts that were simply never reached before -- the known Samsung de-concatenation family; the rest of the suite is unchanged.

start.sh: auto-restart is now the default (--no-loop disables), so an intermittent FX2 USB stop reconnects instead of ending the session; per-session pcap suffix (.N.pcap) so a restart never overwrites the previous capture; and the repetitive sr_session_stop: session was NULL teardown line is filtered from stderr (real decoder errors still pass).

Validation: test_8 56/0/OK, test_7 65/0/OK, xiaomi_phone 640, xiaomi_cold 473, 4gmodem 327, A55 407/395, S21p 399/375, target S21p 369 -- all RESULT: OK, 0 CONCAT. 65/65 unit tests (10 new). VERSION -> 1.7.0.

v1.5.0: invalid-INS one-byte re-frame (residual CONCATs → 0)

The last CONCAT family (4gmodem/A55_sim2/S21p_sim2) is now reframed at the source, not just gated. All 10 traces report 0 CONCAT:

Trace APDUs CONCAT hits
test_8 56 0
test_7 65 0
xiaomi_phone 640 0
samsung_phone 924 0
xiaomi_mi_a1_coldboot 473 0
4gmodem_coldboot 327 0
A55_coldboot_new_cable 407 0
A55_coldboot_new_cable_sim2 395 0
S21p_coldboot_new_cable 399 0
S21p_coldboot_new_cable_sim2 375 0
  1. One-byte re-frame on invalid INS. When a 5-byte header window passes plausible_cla() but the INS is unusable (0x00, 0x6x/0x9x, or odd LSB — ISO 7816-4 §12.1.1), the window is almost always shifted by one stray leading byte (e.g. a leftover SW2 read after a PACKETEND). The old code silently dropped all 5 bytes plus resync (_resync = True), and when resync_idle() gave up on a busy burst the next byte became a bogus CLA whose P3 swallowed the whole dialog into one CONCAT packet. Now the decoder drops only the leading byte (explicitly logged via _note_discard), re-frames the remaining four via _replay, and lets the next decode step start a fresh header at the old INS. Example (4gmodem): the stray 0f after the READ BINARY SW1 91 re-frames 0f 00 a4 08 04 → 00 a4 08 04 02, recovering the true SELECT 00 a4 08 04 02 2f 00 → 61 1c verbatim.
  2. No-silent-discard invariant. Every byte the decoder consumes without emitting is now explicitly logged via _note_discard(value, reason, idle=...). idle=True discards (0x00/0xFF idle stretches, NULLs, stuck low) are rate-limited to the 1st + every 256th; idle=False discards (suspicious CLA, invalid-INS re-frame byte, non-SW bytes in read-until-SW scans) always put an ANN_WARN and the reason. Idle-line noise, suspicious-CLA, stuck-low, and idle-byte-in-header consumers all go through _consume_first() (which pops _replay before peeked_byte) so re-framed bytes cannot infinite-loop.
  3. _consume_first() semantics. read_byte() pops _replay.popleft() first and only falls through to the wire; peek_byte() returns _replay[0] first. Neither updates peeked_samplenum, so the re-frame branch explicitly restores self.peeked_samplenum = es (the first byte's sample) before pushing the 4 remaining bytes — the next header annotates from a valid sample number.
  4. Counters. reset() initializes _discard_total / _idle_discard_total; every _note_discard line carries "discards so far: N" for session-level triage.

The CONCAT detector (embedded_exchanges(), v1.4.0) stays as a regression gate and now reports 0 on every trace. VERSION → 1.5.0. Baseline regenerated.

Phase B status (v1.5.0). Two edge-reader hardening fixes shipped, both verified byte-neutral on all 10 traces (stored baseline unchanged):

  • _next_start_fall() now rejects sub-ETU phantom falls (a genuine start fall must stay LOW for >= half an ETU) — B2.
  • _read_byte_edges() re-anchors forward on a spurious latch instead of dropping the byte (a drop fabricates a 0x00 / shifts the boundary) — B1.

Root cause of the Samsung/xiaomi phone-trace concatenation (the B1/B2 family) is fixed at the source by the v1.5.0 invalid-INS re-frame — the A55 burst cases decode clean with 0 CONCAT. The residual 4gmodem/A55_sim2/S21p_sim2 family (leftover-SW2-shifted header) is also gone. The planned B3 (strict positional genuine-start anchor in the no-idle resync path) directly conflicts with the documented 0.5-vs-1.5-ETU guard trade-off for fast phone ETUs and risks the Samsung de-concatenation; it needs a dedicated design + live validation, not an incremental patch.

v1.3.0: starts_with_atr option removed

The entire ATR-included mode was redundant: its only mode-specific logic was a start-state bootstrap (FIND START vs DATA) and an early trust hint for clock_skip=372, both of which mid-session decoding reproduces via the warm-reset / cold-boot re-arms already handled in state == 'DATA' (starting the hunt instead of a fixed initial state). Every trace in the suite produces identical APDU/GARBAGE/CHKSUM results with the option removed. Removed:

  • The starts_with_atr decoder option (schema + the 6 branching sites in pd.py: initial state, _clock_skip_confident bootstrap, the handle_atr samplenum save/restore, the cold-boot re-arm guard, and the ETU re-measure condition — now self.bit_samples is None or self._pps_speed_changed).
  • --starts-with-atr from start.sh (now warned as obsolete).

The decoder always starts in DATA and re-arms the ATR hunt as needed.

v1.2.1: cold-boot capture support

A capture that starts pre-power-up (VCC/RST low at t=0) previously locked a bogus ETU (bit_samples=1548, clock_skip=369) from pre-ATR power-up DATA transitions in mid-session mode, so the real ATR never synced. Fixed in 241b7ed:

  • Priming. First decode_step reads the initial RST/VCC levels instead of defaulting last_rst/last_vcc to 0 (which fabricated a reset edge).
  • Cold-boot re-arm. RST low at capture start → arm the hunt at the spec-default rate (FIND START, clock_skip=372, no ETU lock).
  • Guarded deassert re-arm. The 10 ms-hysteresis-confirmed deassert lands mid-ATR on warm resets; it only re-arms when state == 'DATA' so it no longer garbles the in-flight ATR read (test_8 mid-session CHKSUM 18→0, test_7 ATR-included 2→0).

New fixtures xiaomi_mi_a1_coldboot_sample.sr / 4gmodem_coldboot_sample.sr decode their full ATR in both modes with 0 GARBAGE.

v1.2.0: start-bit deglitch (Samsung de-concatenation)

Samsung phone traces with gated CLK and non-default F/D (16 CLK/ETU) produced concatenated APDUs: multiple T=0 exchanges merged into a single GSMTAP packet. The v1.1.9 fixes (turnaround idle handling, edge-list deglitch) improved other phone traces but the Samsung trace still showed concatenation because the CLK-synchronous reader's start-bit detector could not use the edge-list deglitch filter.

Fix applied (v1.2.0):

  • Add a 2-sample deglitch in wait_data_falling(): after the 1.5-ETU minimum-high guard passes, skip 2 additional samples and re-check DATA. If DATA returns to idle, the start bit was a glitch → continue hunting. This eliminates 1-sample (62.5 ns) LOW glitches in inter-byte guard times that caused byte-level misalignment in the CLK-sync reader.

Results:

  • Samsung mid-session: 52 → 924 APDUs (de-concatenated), all valid ISO 7816 commands (SELECT, GET RESPONSE, READ BINARY, STATUS, STK envelope), 0 GARBAGE.
  • test_7 ATR: 10 → 65 APDUs, all 37/37 reader exchanges now captured (was 10/37 in v1.1.9 due to ATR resets fragmenting the session).
  • test_8 ATR: 54 → 56 APDUs, 28/37 reader exchanges (unchanged — 9 missing are pre-capture, not a decoder issue).
  • Xiaomi mid-session: 620 APDUs (unchanged, no regression).

Glitch rejection measurements (-l 5 session log):

Trace Glitches rejected Notes
test_8 (reader) 6 Constant CLK, minor noise/turnaround artifacts
test_7 (reader) 14 Constant CLK, more activity than test_8
xiaomi (phone) 0 Edge-list _deglitch_edges() filters before wait_data_falling
samsung (phone) 1041 CLK-sync reader has no upstream deglitch, confirms FX2LP pull-up hypothesis

Xiaomi shows 0 because the edge-list reader's _deglitch_edges() (0.2×ETU threshold) removes sub-ETU pulses before they reach wait_data_falling(). The CLK-sync reader has no equivalent filter, so Samsung catches every glitch. The 6–14 glitches on reader traces are minor noise or turnaround artifacts in the constant-CLK captures.

The 2-sample advance in wait_data_falling shifts _start_fall by 2 samples, but at Samsung's 16 CLK/ETU (~72 samples) this is negligible (<3% of a bit period) and does not affect downstream byte reading.

Design note: magic number. _min_pulse_samples = 2 is tuned for the primary 16 MHz sample rate (2 samples ≈ 125 ns, well within the FX2LP pull-up rise time of 200–500 ns). At other sample rates the value would need adjustment — but since all current traces are 16 MHz, this is left as a hardcoded constant rather than a decoder option. If 12 MHz or 24 MHz traces are added later, consider making it configurable or scaling it from the sample rate.

Logging. Each rejected start-bit glitch is logged with a running count (start-bit glitch rejected (#N)) visible in the session log. This helps diagnose whether the deglitch is too aggressive on a particular capture — if the count is unexpectedly high, the 2-sample window may be filtering real start bits.

Proven data rates (all at 16 MHz sample rate)

Trace ETU (samples) CLK/ETU Mode
test_8 ~43 372 (standard) constant CLK, ATR+PPS
test_7 ~43 372 (standard) constant CLK, warm resets
xiaomi ~53 recovered from DATA gated CLK, mid-session
samsung ~72 16 (F=512/D=32) gated CLK, non-standard F/D
T=0 Procedure Bytes
Byte Meaning
ACK (== INS or == ~INS) Full data match: card acknowledges and expects all P3 data bytes
INS^0x01 or ~INS^0x01 Single-byte match: card validates syntax but processes data one byte at a time
0x60 NULL: card busy, wait for next procedure byte (never an SW1)
0x9E / 0x9F Extended-length: next byte L = number of response data bytes, then SW
SW1 (0x61–0x6F / 0x9X) Status word: exchange complete
CLA (Class) Byte — Interindustry Structure
Bit:  8   7   6   5   4   3   2   1
      b8  b7  b6  b5  SM  SM  ch  ch
  • Bits 8–7: 00 or 01 for interindustry; 1x reserved for proprietary
  • Bit 6: 0 for interindustry; 1 for proprietary structural formats
  • Bits 4–3: Secure Messaging indicator (00 = no SM)
  • Bits 2–1: Logical channel (0–3 for interindustry)

Valid interindustry CLA digits: 0x, 1x, 4x, 5x.

Examples: 0x00 (standard), 0x0C (secure messaging).

INS (Instruction) Byte — Valid Ranges
  • Low nibble cannot be X0 if high nibble is even
  • Low nibble cannot be XF under any circumstances
  • 0x6x and 0x7x ranges are invalid (reserved for SW1 / protocol bytes)

Standard interindustry INS values: A4 (SELECT), B0 (READ BINARY), D6 (UPDATE BINARY), B2 (READ RECORD), E2 (APPEND RECORD), 20 (VERIFY), 82 (EXTERNAL AUTHENTICATE), 88 (INTERNAL AUTHENTICATE).

Quick Validation Checklist
  1. CLA high nibble is 0, 1, 4, or 5 (for interindustry)
  2. INS low nibble is not F
  3. INS is outside 0x6x–0x7x range

Current smoke-test status:

Trace APDUs
test_8 56
test_7 65
xiaomi_phone 640
samsung_phone 924
xiaomi_mi_a1_coldboot 473
4gmodem_coldboot 327
A55_coldboot_new_cable 407
A55_coldboot_new_cable_sim2 395
S21p_coldboot_new_cable 380
S21p_coldboot_new_cable_sim2 356

The baseline runs every trace through the decoder once (intentional since v1.3.0: the starts_with_atr option was removed and the decoder always runs mid-session — it captures all APDUs, including cold-boot ATRs, and is the only mode that works on gated-CLK phone traces).

The four samsung_*_coldboot_new_cable*_sim2 fixtures were captured with the new short cable (30 mm wires, external pull resistors GND→VCC and VCC→DATA), named channels DATA/VCC/RST/CLK on bits 0/2/4/5 at 16 MHz. All four decode their full cold-boot ATR (3b9f9580… on SIM1, 3b9f9680… on SIM2) with 0 GARBAGE / 0 BAD_FCS. S21p SIM2 carries 197 CHKSUM (dirty-wire parity noise, BAD_FCS still 0); A55 SIM2 is clean (0 CHKSUM). The _sim2 fixtures are cropped to the power-on window (the 17–21 s of pre-power idle was removed).

Cold-boot fixtures start before power-up (VCC/RST low at t=0); the decoder must arm the ATR hunt when RST is still low at capture start and decode the full ATR once the card wakes (~17 s in). l8star_coldboot_sample.sr was captured in the same session but had a dirty-wire tail (GARBAGE=1 / RESULT UNCLEAN) and was dropped from the suite.

Note on v1.1.3 fix: The decoder measures CLK period as an average instead of using the minimum recurring period. This correctly handles traces where CLK periods alternate (e.g., 4,3,3 pattern for ~5.33MHz CLK at 16MHz sample rate). The fix changed _measure_clock_period() to use sum(spacings) / len(spacings) instead of _robust_min(spacings), giving accurate spc values like 3.333... instead of 3. This corrected the _wait_clk_rising() skip calculation, fixing the post-ATR byte alignment issue.

GSMTAP wire-format extensions

The GSMTAP-SIM output uses the standard sub_types 0x00-0x03 from libosmocore's gsmtap.h with standard payloads -- APDU, ATR, and the PPS request/response as separate packets (see README.md "GSMTAP events" and the comments in gsmtap_stream.py). It deviates in two documented ways: 0x10/0x11 (RST_EVENT/VCC_EVENT) are custom line-event subtypes, and GSMTAP_FLAG_BAD_FCS writes flags into the header res byte, which official gsmtap.h reserves. The res-byte carriage is this decoder's own extension (upstream simtrace2 never sets res); the semantics mirror simtrace2's per-message USB data flags. 0x10 RST events additionally append the measured CLK frequency when known ([direction, level, flags, clk_hz_be32]; see "v1.9.0" below).

Versioning

The decoder version is defined in pd.py as VERSION = '1.9.1'. The version is printed to the log on decoder startup.

Testing after decoder changes

After any change to pd.py:

  1. Clear bytecode cache:

    find . -name "__pycache__" -type d -exec rm -rf {} +
    
  2. Run all tests against all traces:

    ./tools/capture_baseline.sh > tests/baseline.txt
    
  3. Compare against saved baseline:

    ./tools/compare_baseline.sh
    
  4. If differences found, review:

    • Capture APDU count must stay >0 for any trace that previously had APDUs
    • GARBAGE count must stay 0 for test_8 (mid-session)
    • RESULT must stay OK for test_8 (mid-session)
    • CHKSUM ERROR count must not increase
    • BAD_FCS / payload mismatches / suspicious CLA must not increase
    • ETU values must match for mid-session traces
    • No new INVALID Procedure Byte errors
  5. Run unit tests:

    python3 tests/test_gsmtap.py -v
    
  6. Update tests/baseline.txt with new baseline if changes are intentional.

What happened: the decoder rewrite attempt

We attempted a major rewrite of the ISO 7816 decoder (pd.py) with these features:

  1. Edge-counting always — removed the native_fast sample-skip bit reader, making all bit reads count CLK edges per bit instead of skipping clock_skip * samples_per_edge samples. The idea was drift-immunity.

  2. Signal degradation recovery — a degraded flag tracking rolling parity errors; when ≥ 8 of 64 frames fail parity, the decoder re-arms the ATR hunt and flags APDUs with GSMTAP_FLAG_BAD_FCS.

  3. Clock-drift monitor — every 128 bytes the decoder re-measures the CLK period and re-anchors samples_per_edge if the median drifts > 2%.

  4. Fatal TCK check — the ATR's TCK checksum mismatch was made fatal (reject the ATR) instead of being logged as a warning.

  5. Synthetic ATR fallback — after 8 failed ATR hunts, commit a minimal T=0 ATR [0x3B, 0x00] and begin decoding, for mid-session captures.

Outcome

The rewrite introduced a regression: 35 garbage APDUs on test_8 where the baseline had 0 garbage. The root causes:

  1. Fatal TCK check — the ATR in the example traces has a wrong TCK (got=f7 expected=80) due to a bit error in the capture. The fatal check rejected this real ATR, preventing the decoder from ever reaching the DATA state.

  2. Signal degradation ATR re-arm — the degraded flag triggered on the capture's natural bit errors, re-arming the ATR hunt mid-session and fragmenting the APDU stream.

  3. Stale .pyc cache — the Python bytecode cache was not regenerated after code changes, causing the running decoder to use old code. This masked the real regression for several test runs.

The edge-counting change itself may also have contributed subtle bit-sampling differences, but the TCK check and signal degradation were the primary causes.

Resolution

We reverted to the known-good baseline (2055d1c, the VCC/RST hysteresis commit) and applied only three essential, minimal fixes on top:

  1. hasT0/hasT1 init in start() — initialize both to False for protocol=auto, preventing AttributeError when starts_with_atr=false enters DATA state without an ATR.

  2. hasT0=False guard in decode_step DATA state — when no protocol is known, skip byte reading and wait for a warm reset to trigger the ATR hunt.

  3. Synthetic T=0 ATR fallback — after 8 failed ATR hunts, commit [0x3B, 0x00] and set hasT0=True so the decoder can begin processing APDUs in mid-session captures.

The native_fast sample-skip, signal degradation, clock monitor, and fatal TCK check were all discarded. The decoder is now the original 2055d1c code plus 24 lines of mid-session support.

Current architecture (v1.1.1, post-ATR desync fixes)

The decoder uses a CLK-synchronous bit reader for native-CLK captures and an edge-list DATA reader for the non-native clock modes. Bit timing comes from counting real CLK edges, not from a sample-count estimate.

Two bit readers (selected per burst)

Reader Timing source Used when
_read_byte_clk() count clock_skip CLK rising edges per ETU, sample DATA at bit centres native clock mode and clock_skip known (_clock_skip_confident)
_read_byte_edges() DATA-edge reconstruction from bit_samples sample_as_clock/detect, or mid-session before clock_skip is recovered

Key changes

  1. CLK-synchronous reader. _read_byte_clk() counts clock_skip CLK rising edges per ETU and samples DATA at the bit centres (1.5 … 9.5 ETU). Exact for 0x00/0xff (too few DATA transitions for the edge reader) and deterministic, because clock_skip is protocol-defined (372 for the ATR, FI/DI after PPS). Safe across Clock Stop: CLK never stops mid-character and resumes before the next start bit. _wait_clk_rising() skips most of each bit by samples then lands on the exact edge, so it is fast.

  2. No synthetic ATR. The old [3B, 00] fallback fabricated a 2-byte ATR from a stray 0x3B/0x3F byte in command traffic (e.g. the FID 3F00 of a SELECT) and destroyed the command. The hunt is bounded and never emits a fake ATR.

  3. Command detection during ATR hunt. A plausible CLA + valid INS is replayed to the DATA state and decoded as a command instead of skipped as "invalid TS" — this recovers a SELECT when the preceding ATR was missed.

  4. RST resets clock_skip to 372 on RST assert (a reset makes the card send ATR at the default rate).

  5. PPS on the native path just updates clock_skip from FI/DI (CLK period is unchanged, so the new ETU is exact). No DATA re-measurement burst is consumed — previously that silently dropped the first post-PPS command.

  6. Mid-session clock_skip recovery. _measure_etu() recovers bit_samples; _measure_clock_period() recovers _samples_per_clock; _derive_clock_skip_from_etu() sets clock_skip = bit_samples / _samples_per_clock and marks it confident. If the CLK period cannot be measured (fully gated CLK), the edge-list reader is used instead.

  7. Data handling. Valid APDUs are emitted clean; ambiguous frames are emitted flagged GSMTAP_FLAG_BAD_FCS (never silently dropped); genuine idle-low all-zero noise remains suppressed.

Testing

  • test_8 / test_7: NOT YET PASSING. 0 garbage, but decoder output does not match reader log (T=0 framing groups exchanges incorrectly). See success criteria above.

Mid-session phone decode (legacy note, still applies)

For a live mid-session phone capture (protocol=T=0), the decoder now:

  • Recovers the ETU from the live DATA line via _measure_etu() (edge-list, locked once) so a gated/stopped CLK at a fast ETU (e.g. ~53 samples) is decoded instead of mis-read at the 372-clock default.
  • Decodes bytes with the edge-list reader _read_byte_edges (the only reader now), which is drift-immune.
  • Runs the normal T=0 framing so each command+response exchange is emitted as one APDU.

Validation: test_8/test_7 0 garbage in both modes; 12 unit tests pass; phone 16M/24M decode to coherent APDUs with the STK text fully readable and no 0xff/0xfc garbage.

T=0 case 3/4 command-data (RESOLVED)

Commands that carry command-data (e.g. 80 12 … d0, P3=208) send those P3 bytes on the wire before the card's first procedure byte. The framing now distinguishes the cases by the card's first procedure byte:

  • If the first post-header byte is the ACK (== INS) → case 2/4: the terminal sent no command data; read P3 response bytes (+SW).
  • Otherwise the byte is terminal command data → case 3/4: read P3 command-data bytes, then the card's procedure byte (ACK/SW/9E/9F). On ACK (case 4) the response is read P3 response bytes (+SW).

This consolidates case-3/4 exchanges (e.g. the 80 12/80 14 STK envelope commands) into one C-APDU = header + command data, R-APDU = response + SW APDU, instead of fragmenting them across frames. It is gated to _edge_read (mid-session / gated-CLK captures) so ATR-based captures (test_8 / test_7) keep the original framing unchanged and stay at 0 garbage.

All paths use P3-bounded reads (v1.1.1 reverted the read-until-SW experiment from v1.1.0 which mis-identified FCP 0x62 as SW1).

Decoder methods tried — reliability registry

A running log of decoder approaches, so future work does not re-litigate discarded ideas. "Proven" = kept in pd.py; "Rejected" = do not re-add.

Proven reliable (kept)

  • Sample-skip bit reader (native_fast). Original reader; advances bit timing with single sample-skip waits. Reliable for ATR-based captures (test_8/test_7, 0 garbage). Keep for those.
  • ATR TS validation + resync. Validate TS (0x3B/0x3F); resync on the next fall if bogus. Reliable; stops a phantom start bit shifting the ATR off-by-one.
  • Warm-reset re-arm (guarded). RST deassert → re-arm the ATR hunt (FIND START, clock_skip 372, cleared ETU) only when state == 'DATA' (hunt genuinely idle). Deasserts that arrive while FIND START/ATR is in progress just log "RST deasserted (hunt/ATR already in progress)" and leave state alone — an unguarded mid-ATR re-arm corrupted the in-flight ATR read (test_8 mid-session CHKSUM 18→0, test_7 ATR-included 2→0 after the guard). Reliable; re-ATRs parse at the default rate.
  • Cold-boot priming. One-shot on the first decode_step: wait({'skip': 0}) reads the initial VCC/RST levels instead of defaulting last_rst/last_vcc to 0. Without this, a capture that starts pre-power-up fabricated a spurious reset at sample 0.
  • Cold-boot re-arm. When the capture starts with RST low (VCC not yet on), arm the hunt immediately regardless of start conditions: state FIND START, _atr_hunt_count=0, clock_skip=372, bit_samples=None (no ETU lock), so the pre-ATR power-up DATA transitions cannot lock a bogus ETU (bit_samples=1548, clock_skip=369 before this fix). Logs "RST low at start: expecting cold-boot ATR". Decodes the full cold-boot ATR on xiaomi_mi_a1_coldboot_sample.sr / 4gmodem_coldboot_sample.sr (0 GARBAGE).
  • 1.5-ETU start-bit guard. Rejects the phantom 0x00 an idle glitch inserts before an ATR. Reliable.
  • VCC/RST 10 ms level-stability hysteresis. Reports a level only after ≥10 ms stable. Reliable; symmetric power-up/down, kills spurious events from a ringing/floating sense line.
  • PPS speed-switch follow (clock_skip = F/D). After an accepted PPS the native skip becomes F/D CLK cycles/bit. Reliable (verified live).
  • T=1 block-chain follow-up bound. Caps chained I-blocks so garbage cannot loop forever. Reliable.
  • Synthetic T=0 ATR fallback [0x3B, 0x00]. After 8 failed ATR hunts, commit a minimal ATR and set hasT0=True. Reliable for mid-session starts (no ATR in the trace).
  • ETU auto-detect from DATA via edge counting (_measure_etu). Edge-waits to the first DATA start-bit fall, measures ETU from DATA-edge spacing, locks it once. Reliable for gated/stopped CLK (phone, ~53 samples). Locking once (not re-measuring) is drift-immune and avoids glitch re-anchors.
  • Edge-list bit reader (_read_byte_edges). Per-byte edge reconstruction from the DATA edge list (re-anchors the next byte via _next_start_fall). Drift-immune. Reliable for mid-session/edge mode; gated by _edge_read.
  • decode_step unified dispatch. One state machine handles ATR/PPS/DATA + mid-session. Reliable; current architecture.
  • hasT0/hasT1 guards + init. Prevents AttributeError and skips byte reading until a protocol is known. Reliable.
  • T=0 case-3/4 ACK==INS discriminator. First post-header byte == INS ⇒ case 2/4 (response bounded by P3); else command data (read P3, then the procedure byte). Reliable for consolidating STK envelope commands. Gated to _edge_read. P3-bounded reads avoid FCP tag misidentification (v1.1.1 reverted read-until-SW from v1.1.0).
  • 1.5-ETU start-bit guard in wait_data_falling. min_high = 1.5 * bit_samples distinguishes genuine inter-byte idle gaps (≥2 ETU per ISO 7816-3) from intra-byte HIGH periods (≤1 ETU). Prevents byte misalignment after _measure_etu() consumption (v1.1.1 fix for post-ATR desync).
  • Inverse-convention ATR detection in DATA state. firstByte == 0x3f alongside 0x3b at line 1656, so inverse-convention ATRs (TS=0x3F) are parsed by the default state. Sets clock_skip=372 correctly before PPS (v1.1.1 fix).
  • _resync = True after PPS acceptance (native CLK path). Forces resync_idle() before the first post-PPS command, preventing the decoder from latching onto a mid-byte transition at the new speed (v1.1.1 fix).

Tried and rejected (do not re-add)

  • Edge-counting as the sole bit reader (remove native_fast entirely). Subtle per-bit sampling differences regressed test_8 (35 garbage). Edge-counting is fine as a second reader (_read_byte_edges) used only in mid-session mode; it is not a drop-in replacement for the whole pipeline.
  • Signal-degradation ATR re-arm (degraded flag on ≥8/64 parity errors). Triggered on the capture's natural bit errors, re-armed the ATR hunt mid-session, and fragmented the stream. Rejected.
  • Clock-drift monitor (re-measure CLK every 128 bytes, re-anchor samples_per_edge). Unneeded: locking the ETU once is sufficient and safer. Rejected.
  • Fatal TCK check. The example ATRs carry a wrong TCK (capture bit error, got=f7 expected=80); fatal rejection blocked the DATA state entirely. TCK must stay a non-fatal warning. Rejected.
  • CLA/P1P2 heuristic routing to T=1. Misread real T=0 traffic as T=1. Rejected.
  • parse_packet heuristic / APDU-boundary guessing from CLA/P1P2 + Le/ALG tables. Produced false splits and mis-framed exchanges. Rejected in favor of proper T=0/T=1 transport state machines.
  • ignore_rst / ignore_vcc options. Superseded by channel assignment + hysteresis. Rejected.
  • Generic "read response until a 6x/9x status word" for T=0 framing. Any 0x6x/0x9x byte (e.g. command-data 0x6c, FCP 0x6f) was taken as SW1, truncating/fragmenting exchanges and dropping most of the capture. Rejected; replaced by the ACK==INS discriminator (case 2/4 bounded by P3) with P3-bounded reads for all paths (v1.1.1 reverted the read-until-SW experiment from v1.1.0 which mis-identified FCP 0x62 as SW1).
  • 0.5-ETU start-bit guard in wait_data_falling (for _edge_read). min_high = 0.5 * bit_samples was too small for slow ETUs — it accepted intra-byte HIGH periods (data bit transitions) as start bits, causing byte misalignment after _measure_etu() consumption. Replaced by 1.5-ETU guard in v1.1.1.

Open residual limitations

  • Mid-session captures that begin inside an exchange cannot frame the first command perfectly (expected; the rest of the stream is clean).
  • Samsung phone — gated CLK, non-default F/D (samsung_phone_sample.sr). Uses F=512/D=32 (16 CLK cycles/bit). _measure_etu correctly measures the ETU from DATA edge spacings (after glitch filtering). Now passes with 0 GARBAGE and de-concatenated APDUs after v1.1.10 deglitch fix.

v1.1.6 fix: bounded T=0 loops and explicit EOF handling

Tightened the edge-read T=0 procedure-byte handlers to prevent runaway reads and to surface end-of-capture explicitly.

  1. Bounded all "read until SW" / turnaround-skip loops. Replaced the unbounded ACK-handler while and the open-ended range(512) loops with for _ in range(MAX_TPDU_LEN). Added EOF checks so the decoder returns cleanly at end-of-capture instead of consuming zeros/turnaround bytes indefinitely.

  2. read_byte() / peek_byte() return None on EOF. Previously both methods returned 0x00 when the sample stream ended, making it impossible for callers to distinguish real data from padding. They now return None; the T=0 DATA-state header and procedure-byte loops check for None and exit the current exchange.

  3. Skip turnaround idle bytes before appending. The P3=0 and case-4 ACK "read until SW" paths now mirror the v1.1.5 unexpected-byte fix: non-SW bytes (including 0xFF turnaround artifacts) are skipped before the status word is appended, rather than being added to the packet.

v1.1.5 fix: turnaround idle bytes in edge-read path

Samsung phone traces with gated CLK had 5 garbage APDUs (BAD_FCS) in mid-session mode. Root cause: two code paths in the edge-read T=0 procedure-byte handler did not skip turnaround idle bytes (0xFF) on the bidirectional DATA line.

  1. ACK handler (case 2/4): After reading P3 response bytes, the code read 2 raw bytes as SW1 SW2. For case-3 commands (SELECT with data), the terminal sends command data after ACK, then the DATA line idles (0xFF) before the card sends SW. The idle 0xFF was mis-identified as SW1. Fixed by adding a while loop that skips non-SW bytes before reading SW1.

  2. "Unexpected byte" handler (procedure byte loop): Non-SW bytes (e.g. 0xFF turnaround) were appended to the packet before scanning for SW, corrupting the SW position. Fixed by moving packet.append(pb) inside the SW1 check so non-SW bytes are skipped.