catarrh 9ef1a59f2c v3.23.1: the PLI dictionary defaults and the PLI codec tag fixes
An unconfigured PLI dictionary answered result-ok with no data object,
which confuses applications that expect data.  The dictionary now has a
base layer of sensible defaults for the qualifiers the pinned ETSI specs
define (TS 102 223 8.x, tags per TS 101 220 V18.3.0 Table 7.23):

- location as the test network 001/01 + LAC 0000 (8.19),
- the classic test IMEI 490154203237518 as F-padded BCD (8.20) and its
  IMEISV (8.74),
- language 'en' (8.45), Timing Advance (2E/AE), E-UTRAN (8.61; UTRAN +
  E-UTRAN for the multiple-technology qualifier 0E),
- automatic search mode (8.75), a full battery (8.76).

An override set through /api/pli-dict wins, and clearing a field restores
its default (the PWA's Save re-renders the effective values; the GET returns
the override or the default for the full qualifier set).  The date/time
qualifier stays empty so the host clock keeps answering it; the
3GPP/3GPP2-specific qualifiers (NMR, ESN, MEID, CSG/HNB, WLAN, slices,
CAG, ...) stay empty - the ETSI specs define no contents for them, and a
fabricated object would mislead the application more than no answer.

Verifying the values against the pinned tag table exposed pre-existing bugs
in the PWA's PLI inline codecs, fixed here:
- Timing Advance used C6 (a 3GPP2 tag) -> 2E/AE;
- IMEISV used 94 (the IMEI tag) -> 62/E2;
- Network Search Mode used AD (the Language tag) -> 65/E5, and its labels
  were swapped ('00' Manual / '01' Automatic per 8.75);
- the battery field was a percentage where 8.76 is an enum ('00' very low
  ... '04' full, 'FE'/'FF');
- encImeiPli padded the odd 15th digit with 0 instead of F (TS 124 008).

Docs: help EN/RU, api.md, the guide.  Tests: the defaults + the resolution
order (Python), the HTTP endpoint's defaults/override/clearing, the codec
tags/labels and a server-defaults drift guard (Node).  846 frontend +
829 Python; sw cache simple-v414.
2026-10-07 09:46:39 +03:00
catarrh ad2a253f2a PLI date/time responses default to the host clock
Live finding (Network rejection events): the card asks the terminal for the
current date and time (PROVIDE LOCAL INFORMATION, qualifier 03) and our TR
answered "performed successfully" with no data.  TS 102 223 6.4.15 says the
terminal shall return the current date and time, and the 6.8.0 TR structure
requires the Date-Time and Time zone object (8.39) for that qualifier.

- _pli_data_hex(qual): the TR Config dictionary entry wins; when it is empty
  the date/time qualifier is answered from the host clock via _encode_scts
  (the SMS timestamp builder, TP-SCTS coding).
- _build_tr and _DefaultProactiveHandler put the command-specific data objects
  after the Result TLV per the 6.8.0 order (the POLL INTERVAL Duration echo
  too; real terminal responses pin the order: 8103010300 02028281 030100
  0402011E).
- _decode_tr decodes qualifier 03 with the same 8.39 coding (swapped
  semi-octet BCD digits, time-zone sign bit 0x08, 'FF' = unknown); it read
  plain decimal bytes and a 0x80 sign before.
- The PWA PLI dictionary codec for the date/time entry writes the same coding
  (it wrote plain hex bytes and a 0x80 sign), and the TR Config panel notes
  the empty-entry default.  sw cache simple-v351.

Tests: builder vectors (east/west/unknown zone) + dictionary override + the
empty non-date/time qualifier + the object order (PLI and POLL INTERVAL) + the
handler path + the TR decode + a frontend codec round-trip test.
2026-10-01 23:37:26 +03:00