Commit Graph
100 Commits
Author SHA1 Message Date
Harald Welte 981220641d pySim.esim.saip.File: Turn file_size into a computed property
This way, we can use file_size for both record-oriented and transparent EF

Change-Id: Ib787cabe969202073a8c10042e200f3d2c29db73
2024-09-03 21:57:47 +02:00
Harald Welte 73dd3d0637 pySim.esim.saip: Add missing initialization of File.df_name
Change-Id: Iaf596a8914850ccae584c3b78dc7711db736ac80
2024-09-03 21:57:47 +02:00
Harald Welte 65cbe48953 pySim.esim.saip: Another naming irregularity.
The choice member is called df-5gprose but the header is called
'df-5g-prose-header' (note the '-' between '5g' and 'prose'). WTF.

Change-Id: I86004ac2e18a187c26c5e470344908512d21fb9e
2024-09-03 21:57:47 +02:00
Harald Welte 52735f3685 pySim.esim.saip: Fix weird DF names
Sometimes the struct member is called like df-telecom, but in other
cases it's called df-df-saip  with a double 'df' in front.  That makes
no sense, but we have to deal with it from our constructors...

Change-Id: If5e670441f03a47fa34e97a326909b24927c12f7
2024-09-03 21:57:47 +02:00
Harald Welte 9036d6d3fb remove pySim.gsmtap as it has moved to osmopython.gsmtap
Change-Id: I631bb85bc6e76b089004d9f2e2082d70cbccf200
2024-09-03 21:57:47 +02:00
Harald Welte a3962b2076 Migrate over to using pyosmocom
We're creating a 'pyosmocom' pypi module which contains a number of core
Osmocom libraries / interfaces that are not specific to SIM card stuff
contained here.

The main modules moved in this initial step are pySim.tlv, pySim.utils
and pySim.construct. utils is split, not all of the contents is
unrelated to SIM Cards.  The other two are moved completely.

Change-Id: I4b63e45bcb0c9ba2424dacf85e0222aee735f411
2024-09-03 21:57:47 +02:00
Harald Welte a437d11135 contrib/jenkins.sh: Install dependencies before calling pylint
This is the only way we can make sure pylint has all required
information about imports from packages we depend upon.

Change-Id: I29582aa3d7f9ace9ce832d5b907420aaf14881fb
2024-09-03 21:56:19 +02:00
Harald Welte 8ac2647004 contrib: script to generate "update" commands from diff of fsdumps
Change-Id: I08897cd353093575f98c68580afbc68b6f2f878f
2024-08-31 13:12:05 +00:00
Harald Welte f807983a98 pySim.esim.saip: Add missing entry for 'rfm' to class4petype
Change-Id: I5fec2b026fc6a1197fc1e18d880ea6d10fd4a611
2024-08-27 14:23:40 +00:00
Harald Welte a5e2a8dbfd contrib/saip-tool: Add 'tree' command to display filesystem tree of profile
Change-Id: I5cda7ef814648543c63938ac6a4fb9dba79379ff
2024-08-23 06:51:07 +00:00
Harald Welte a86b1abc03 osmo-smdpp: Proper error handling in case ctxParams1 is missing member
************* Module osmo-smdpp
osmo-smdpp.py:373:15: E0601: Using variable 'iccid_str' before assignment (used-before-assignment)

Change-Id: I52bef18cbcc9f5d14519ff1473532c8502d45908
2024-08-23 06:51:07 +00:00
Harald Welte 6d4c566fd7 Fix pySim.esim.es2p.Param.timestamp._encode
************* Module pySim.esim.es2p
pySim/esim/es2p.py:107:19: E1101: Class 'datetime' has no 'toisoformat' member (no-member)

Change-Id: Ib762792d595048bf6d7d6f5acbe2715f137ae5bb
2024-08-23 06:51:07 +00:00
Harald Welte c6f8457ff1 pySim.esim.saip: maintain a parsed fileystem hierarchy
With this change, the ProfileElementSequence object will maintain a
representation of the filesystem hierarchy of the eSIM profile.  Every
file that is added by a ProfileElement will add a FsNode into that tree,
and each FsNode will point to the File object for the respective file.

This allows us to find files by their path, as well as add files by
path.

Change-Id: I2caadc24b1087855f23f3c57cdf8dabbf81757c0
2024-08-23 06:51:07 +00:00
Harald Welte cd22b9aee3 pySim.esim.saip.File: move away from stream for file content
Let's linearize the file content in a bytes member variable self.body.

Change-Id: I6cb23a3a644854abd3dfd3b50b586ce80da21353
2024-08-18 19:38:44 +02:00
Harald Welte 39613da6a7 pySim.esim.saip: Fix key used in FsProfileElement.files2pe
The self.files member is a dict.  Hence we should use those dict
keys when [re]building the decoded dict. The previous code ignored
it and re-constructed the key from File.pe_name - but that's not
always identical.

Change-Id: I0e6c97721fb1cfc6b5c21595d85bd374d485b573
2024-08-18 19:38:44 +02:00
Harald Welte ab3e04fdb1 pySim.esim.saip: Fix typo in ProfileElementAKA.set_mapping() method
Change-Id: Icd1594c6c2a8536a4ab8d1fc698307f05f539bdb
2024-08-18 19:38:44 +02:00
Harald Welte 3a95fa12f6 pySim.esim.saip: Add some more docstring comments
Change-Id: I70cf2b4dff1952f581efa3b21211c542f43ce565
2024-08-18 19:38:44 +02:00
Harald Welte b349149a88 pySim.esim.saip: Back-reference from ProfileElement to ProfileElementSequence
Store a back-reference to the PE-Sequence in the PE object; this is
neccessary for some upcoming patches, e.g. to determine the position in
the sequence, access the global filesystem hierarchy, etc.

Change-Id: I24b692e47e4dd0afb5a17b04d5e0251dded3d611
2024-08-18 19:38:44 +02:00
Harald Welte 3b30994ff0 pySim.esim.saip: pass up **kwargs from ProfileElement sub-class constructors
Change-Id: Ib2b7f6d7428d03e9a8c23af39a61f450096c12bc
2024-08-18 19:38:44 +02:00
Harald Welte 6a1e5eb4ee pySim.esim.saip: Move AKA specific post_dec + pre_enc to AKA subclass
Having AKA specific code in the generic ProfileElement base class dated
back to when we didn't have a ProfileElementAKA subclass.

Change-Id: Icd332183758b8ef20a77507b728f5e455698def0
2024-08-18 19:38:44 +02:00
Harald Welte 31c3c9a1e3 pySim.esim.saip: Refactor file size encoding into a method
Change-Id: I46b8cb81ef8cc1794c11b61e0adfb575f937b349
2024-08-18 19:38:44 +02:00
Harald Welte 6d495fb24d pySim.esim.saip: Improve File.from_template feature support
When populating a File from a FileTemplate, let's make sure we
* correctly treat the maximum file size for BER-TLV files
* respect the default value pattern / repeat pattern
* respect the high_update flag.

Change-Id: I3ba092e0893f53a18264dff5fa37b12ccd9bd47e
2024-08-18 19:38:44 +02:00
Harald Welte 01ddec2fdc contrib/saip-tool: Add command-line arguments to configure log level
Change-Id: I4257d7b76193cdaad8c8571ff49f29067e8ab8c8
2024-08-18 19:38:43 +02:00
Harald Welte b2970d4bbe pySim.esim.saip.oid: Allow OID instance in prefix_match()
So far the prefix_match() required a string argument; let's also
permit another OID object to be passed; we internally convert that
to string.

Change-Id: I0feb7782d1813cc46ec78f170eb0fce804aebe3a
2024-08-16 18:06:12 +02:00
Harald Welte 1f477495ec saip-tool: Set default log level to INFO (instead of DEBUG)
most users don't want to debug the program.

Change-Id: I54ae558cf8d87bf64cc75431cc4edcc694fa9084
2024-08-16 17:46:41 +02:00
Harald Welte 97dfcaa9c7 pySim.filesystem: Permit Path object construction from FID integer list
we so far supported construction of the Path object from a string or
a list of strings.  Let's also add the option of constructing it from a
path consisting of a list of integer FID values.

Change-Id: Ia7e9375b3258d1fbfdc892cefba3e3bbe841c550
2024-08-16 17:46:41 +02:00
Harald Welte 022d562ae1 pySim.ts_102_221: Make sure FileDescriptor for BER-TLV contains file_type
before this change, structure == 'ber_tlv' was missing the
file_type == working_ef attribute.  So for linear_fixed, transparent
and cyclic, the file_type attribute was present, but for ber_tlv it was
missing. This is illogical from a user point of vie and makes downstream code
potentially more complex, as it cannot match on working_ef for all EF
types.

Change-Id: If0076cc6dd35a818c08309885f6ef1c1704052c6
2024-08-15 19:48:25 +02:00
Harald Welte 89dff98fb6 pySim.esim.saip.templates: Introduce dependency/hierarchy information
The SAIP specification is very weird in a way that it treats the DF and
EF descriptions as some kind of flat structure without describing the
hierarchy.  So when creating a DF, sometimes it should be created below
the current DF, and sometimes it should be adjacent next to the current
DF.

Let's introduce
* a 'ppath' property of FileTemplate to indicate if a file is anything
  but a direct sibling of the 'base DF' of the PE
* an 'extends' property of ProfileTemplate to indicate that a given
  template does not have its own 'base DF', but that its contents merely
  extends that of another ProfileTemplate
* a 'parent' property of ProfileTemplate to indicate a parent
  ProfileTemplate below whose 'base DF' our files should be placed.

Change-Id: Ieab4835cd21008b289713784c0eb7170af2ccfb9
2024-08-15 19:48:25 +02:00
Harald Welte 7d9c6583ef pySim.cards: Make file_exists() check for activated/deactivated
The Card.file_exists() method is only called by legacy pySim-{read,prog}
when it wants to determine if it can read/write a file.  Therefore
it actually doesn't only want to know if the file exists, but also
if it's not deactivated.

Change-Id: I73bd1ab3780e475c96a10cd5dbdd45b829c67335
Closes: OS#6530
2024-08-07 14:10:21 +00:00
Harald Welte 10e9e97724 pySim.esim.saip.templates: Add expand_default_value() method
This method can be used to expand the default value pattern of the
file system template for the file to the specified (record, file) length.

Change-Id: Id3eb16910c0bdfa572294e14ca1cd44ca95ca69f
2024-08-05 15:56:15 +00:00
Harald Welte 8f5fd37b4a pySim.esim.saip.templates: Fix '...' notation in default value
The default value must contain '...' to indicate a variable-length
default value section, not '..'

Change-Id: I8d78278065c145b86460acf8eb723babe777c4f6
2024-08-05 15:56:15 +00:00
Harald Welte ca1b00f99e pySim.esim.saip.templates: Explicitly specifiy repeatable default value
Change-Id: I9ae2c36f5bffac392c1219bb6ea21c1c05dff4b9
2024-08-05 15:56:15 +00:00
Harald Welte 465d1a07e0 pySim.esim.saip.templates: Add SaipSpecVersion
The SAIP specification version implicitly determines which filesystem
templates (or versions thereof) are supported.  So if a given eUICC
states it implements SAIP version 2.3.0, then we have to translate
this into which template versions that means.  The new SaipSpecVersion
and its derived classes do exactly that.

Change-Id: I3a894c72c22e42bd2067e067be80a67197ad1bf2
2024-08-05 15:56:15 +00:00
Harald Welte 5b513a543f pySim.esim.saip.oid: Fix OID defininitions for v3.3.1 IoT templates
Change-Id: Iac620362ae9336199f3b3b168a4bfeda3e2b7c35
2024-08-04 12:46:12 +02:00
Harald Welte 46bc37fa65 pySim.filesystem: Add __len__ method to Path object
This returns the length of the path.

Change-Id: I5e3ba726ed180405c4218ebeee240a3a40527f99
2024-08-04 12:46:12 +02:00
Harald Welte 19328e3bbd pySim.esim.saip.templates: Update to SAIP v3.3.1 (July 2023)
This new TCA SAIP version introduces a number of aditional templates

Change-Id: Ie8aeae3f5b36a3141a70f670c220932389d241a6
2024-08-04 12:46:12 +02:00
Harald Welte d2254377b6 pySim.esim.saip.templates: Add a notion of the path of a file
The SAIP data format is inherently flat and doesn't intrinsically
have an idea of the tree-like structure of a filesystem.  However,
if we want to (for example) convert a physical USIM into an eSIM
profile, we need to find the template for a given file, where the file
is identified by its path.

Let's expose a path property of the FileTemplate object, and populate
that when creating the FileTemplate as part of a ProfileTemplate.

Change-Id: Ie145ba159081daf8fbfa544f6d4248f05b7eea96
2024-08-04 12:46:12 +02:00
Harald Welte 041a1b33fc pySim.esim.saip.template: Permit file-size for BER-TLV files
We previously only permitted this for transparent files (TR), but
file size can of course also be specified for BER-TLV files.

Change-Id: Ie007cf2ccde0a17d0fb853a96b833f064ae52c59
2024-08-04 12:46:12 +02:00
Harald Welte d3a6bbc215 pySim.esim.saip: Add subcasses for EAP, DF.SNPN and DF.5G_ProSe
Change-Id: I8f29e72d387c66c99ceccffc9de23a68fd15dc46
2024-08-04 12:46:12 +02:00
Harald Welte 08d7c10211 pySim-shell: Support other ADMx values beyond ADM1 from 'verify_adm'
Change-Id: Icce6903c1e449889f8bc5003ccfe6af767a26d44
2024-08-04 12:46:02 +02:00
Harald Welte fdae0ff90d pySim-shell: Support hexadecimal ADM pin in 'verify_adm'
Change-Id: I4191ed79ebe7869d8411d280a32ac2d4bbc210e3
Closes: OS#6480
2024-08-01 11:38:18 +02:00
Harald Welte 7c06bcdd57 Support EF.ICCID and EF.PL on classic TS 51.011 SIM
So far we only had the EF.ICCID and EF.PL within our UICC card profile.
However, a classic GSM SIM card is not an UICC, so the CardProfileSIM
also needs those files.

To avoid circular dependencies, move the definitions from ts_102_221.py
to ts_51_011.py

Change-Id: I6eaa5b579f02c7d75f443ee2b2cc8ae0ba13f2fe
Closes: OS#6485
2024-07-31 23:17:13 +02:00
Harald Welte d81c2086c8 pySim.tlv: Fix from_dict of nested TLVs
The existing logic is wrong.  How we call from_dict() doesn't differ if
a member IE itself contains a nested collection: We always must pass a
single-entry dict with the snak-case name of the class to from_dict().

Change-Id: Ic1f9db45db75b887227c2e20785198814cbab0f5
Fixes: OS#6453
2024-07-31 23:17:13 +02:00
Harald Welte d3fb38965b ara_m: Fix pySim.tlv.IE.from_dict() calls
Historically, to_dict and from_dict were not symmetric; this has been
fixed in I07e4feb3800b420d8be7aae8911f828f1da9dab8 in December 2023.

This however broke the ara_m legacy use of the from_dict() methods.
We've just introduced a from_val_dict() method in
I81654ea54aed9e598943f41a26a57dcc3a7f10c2, let's make use of it.

Change-Id: I3aaec40eb665d6254be7b103444c04ff48aac36d
2024-07-29 13:06:27 +02:00
Harald Welte 4fd3fa445c pySim.esim.saip: Add subclasses for gsm-access, phonebook, 5gs, saip
Those are all optional ProfileElements related to the USIM NAA.

Change-Id: I621cc3d2440babdc11b4b038f16acf418bbc88ad
2024-07-29 13:06:27 +02:00
Harald Welte 4f9ee0fa75 pySim.esim.saip: Refactor from_der() method to have class_for_petype()
Change-Id: I2e70dddb0b3adb41781e4db76de60bff2ae4fdb7
2024-07-29 13:06:27 +02:00
Harald Welte 6b1c6a986c pySim.esim.saip.templates: Build tree from template files
Change-Id: I13e80e9dbddbb145411378a0d9e01461aef75db4
2024-07-29 13:06:27 +02:00
Harald Welte 3d6a712e8c Fix missing AIDs in pySim.saip templates
Change-Id: Ie02e2d27ece0fbd9719468c8d31febd1937468f8
2024-07-29 13:06:27 +02:00
Harald Welte 8b1060a30e Reference pySim.filesystem derived classes from SAIP templates
Change-Id: Ia1c810262f1cfa48dae192c7de620c7f0fb69c25
2024-07-29 13:06:27 +02:00
Harald Welte e354ef7d05 pySim.esim.saip: Initial support for parsing GenericFileManagement
Change-Id: I4a92f5849158a59f6acca05121d38adc0a495906
2024-07-29 13:06:16 +02:00
Harald Welte e3e964589f pySim.ts_102_221: Add ProprietaryInformation sub-IEs of TS 102 222
We put those in ts_102_221 because that's where ProprietaryInformation
is defined, and we don't want to risk circular dependencies.

Change-Id: I526acfeacee9e4f7118f280b3549fd04fdb74336
2024-07-29 13:03:21 +02:00
Harald Welte cf65d92039 pySim.ts_102_221: Fix FileDescriptor encoding for BER-TLV case
This fixes a long-standing bug in the FileDescriptor IE class which so
far only supported decoding, but not encoding of BER-TLV file
descriptors.

Change-Id: I598b0e1709ee004bcf01a53beb91f68470e1f3da
2024-07-29 13:03:21 +02:00
Harald Welte f3b3ba15b8 pySim.filesystem: Add Path for abstraction/utility around file system paths
Change-Id: I202baa378988431a318850e3593ff1929d94d268
2024-07-29 13:01:51 +02:00
Harald Welte bff8902ce1 pySim.commands: make use of status word interpreter for CHV
Related: OS#6398
Change-Id: I71efe9d6804c4845bb81f1b3b443215dad0ac301
2024-07-29 13:01:51 +02:00
Harald Welte de5de0e9db pySim-shell: add "fsdump" command
This command exports the entire filesystem state as one JSON document,
which can be useful for storing it in a noSQL database, or for doing a
structured diff between different such dumps.

It's similar to "export", but then reasonably different to rectify a
separate command.

Change-Id: Ib179f57bc04d394efe11003ba191dca6098192d3
2024-07-29 10:48:22 +00:00
Harald Welte d29f244aad pySim.tlv: Separate {to,from}_val_dict() from {to,from}_dict()
There are some situations where we want to work with a type-name-wrapped
dict that includes the type information, and others where we don't want
that.  The main reason is that nested IEs can only be reconstructed if
we can determine the type/class of the nested IE from the dict data.

Let's explicitly offer {to,from}_val_dict() methods that work with
the value-part only

Related: OS#6453
Change-Id: I81654ea54aed9e598943f41a26a57dcc3a7f10c2
2024-07-27 10:30:26 +02:00
Harald Welte eda408fba3 pySim.commands: Don't convert SwMatchError to ValueError
In the read and write command implementations, we used to catch
lower-layer exceptions (usually SwMatchError) and "translate" that into
a value error, only to add more information to the exception.  This
meant that higher-layer code could no longer detect this was actually
a SwMatchError exception type.

Let's instead use the add_note() method to amend the existing exception,
rather than raising a new one of different type.

Change-Id: Ic94d0fe60a8a5e15aade56ec418192ecf31ac5e7
2024-07-27 10:30:26 +02:00
Harald Welte 2a963a7ac0 pySim.runtime: Be more verbose if incompatible method is called
Change-Id: I57190d50a63e0c22a8c5921e1348fae31b23e3d4
2024-07-27 10:30:26 +02:00
Harald Welte 75a109419c pySim.tlv: Add convenience methods to IE class
The new methods allow programmatic resolution of nested IEs from
a parent, assuming there's only one child of a given type (which is
often but not always the case).

Change-Id: Ic95b74437647ae8d4bf3cdc481832afb622e3cf0
2024-07-27 10:30:26 +02:00
Harald Welte d25ea35e7e pySim.esim.saip: Decode each 'File' element in ProfileElement
When loading a ProfileElement from its DER-ecoded format, populate
a dict with a pySim.esim.saip.File object for each file.

Change-Id: Ie2791c10289eb28daed2904467b0c5e5b11c94c2
2024-07-27 10:30:26 +02:00
Harald Welte 6d2e385acf pySim.esim.saip: Add OID comparison functions
Change-Id: Iab642e0cc6597f667ea126827ea888652f0f2689
2024-07-27 10:30:26 +02:00
Harald Welte 34dce409b9 pySim.global_platform.ota: Support KVN 0x70 for SCP02
This is a non-standard extension of sysmocom products.

Change-Id: I00d52f7629aae190ee487ea3453f42b5f94cf42f
2024-07-26 08:38:17 +02:00
Harald Welte c60944a7de saip-tool: Fix TAR display for implicit TAR
Until Change-Id Ifba1048e3000829d54769b0420f5134e2f9b04e1 the TAR
output was working for implicit tar.  With said commit we fixed it
for explicit tar but broke implicit tar.

With this commit it works for both implicit and explicit TAR.

Change-Id: I76133b0e02996a138257f3fba5ceb0d2fc6fad80
2024-07-26 08:38:17 +02:00
Harald Welte 0c022944ff pySim.apdu.global_platform: Decode the INSTALL command parameters
Change-Id: I1c323c1cb1be504c6ad5b7efb0fa85d87eaa8cf7
2024-07-26 08:38:17 +02:00
Harald Welte 4f2a6ebf1f pySim.ota: Add construct definition for SIM File + TK Param definition
Change-Id: Ie5aa2babaf66af49eb5223e5e9d4451089baf055
2024-07-26 08:38:17 +02:00
Harald Welte 87b4f99a90 pySim.apdu: Get rid of HexAdapter
In the past, we always wrapped a HexAdapter around bytes-like data in
order to make sure it's printed as hex-digits.  However, now that we are
doing JSON output it's much easier to let the pySim.utils.JsonEncoder
take care of this in a generic way.

We should do a similar migration all over pySim (pySim-shell,
filesystem, etc.) - but for now only do it in the low-hanging fruit of
pySim-trace aka pySim.apdu

Change-Id: I0cde40b2db08b4db9c10c1ece9ca6fdd42aa9154
2024-07-26 06:20:46 +00:00
Harald Welte c800f2a716 pySim-trace: display decoded result as JSON, not as python dict
This means users can copy+paste or otherwise post-process the data in a
standard format.

Change-Id: I3135f2f52b8d61684a71b836915b43da5c48422b
2024-07-24 10:37:05 +02:00
Harald Welte 699b49ef1b pySim.apdu.ts_102_222: APDU decoding for administrative commands
Change-Id: I77c97221da19e1a67d96f7cfb69785baefc675c0
2024-07-24 10:37:05 +02:00
Harald Welte d93d774dcc pySim.apdu: Fix APDU CLA matching
The cla values as hex strings must be compared in case insensitive manner

Change-Id: I890bc385d6209e6cfe9b0c38bd9deee7ae50e5f5
2024-07-19 18:24:29 +02:00
Harald Welte 289d2343fa pySim.apdu: Refactor cmd_to_dict() method
Let's factor out the "automatic processing using _tlv / _construct" as a
separate method.  This way we enable a derived class to first call that
automatic processing method, and then amend its output in a second step.

Change-Id: I1f066c0f1502020c88d99026c25bf2e283c3b4f5
2024-07-19 18:23:36 +02:00
Harald Welte 03eae595a3 pySim.ts_31_102: Fix name of EF.VBSCA
It's VGCS but VBS.  There's no VBCS.

Change-Id: I3c4a7ec9cd6a56fe7b85832afc68685f8dccbfd1
2024-07-18 12:15:43 +02:00
Harald Welte f174ad6885 ts_31_102: Make use of ts_31_103_shared and add Rel 18 files
Change-Id: I68ca15084f9654468bd37526c02a66322085b25b
2024-07-18 12:15:43 +02:00
Harald Welte 6f5a0498bf [cosmetic] ts_31_102: Note in comment which release introdcued recent files
Change-Id: I0c1250b532992ae954b1d8ab20993cb9fa947695
2024-07-17 18:37:15 +02:00
Harald Welte fb56f35546 move parts of pySim.ts_31_103 to pySim.ts_31_103_shared
This is requird to make some definitions available to USIM / ts_31_102
without introducing circular dependencies.

Change-Id: I32e29f400d2da047e821bf732316b21805b5a1e2
2024-07-17 18:37:15 +02:00
Harald Welte 282aeadcc4 pySim.ts_31_103: update to spec v18.1.0 Release 18
This adds two new EFs and one new IST service.

Change-Id: Iced1700046b459399a3e8305e1387ec65eeb3536
2024-07-17 18:37:15 +02:00
Harald Welte 92bae20b49 osmo-smdpp + es9p_client: HTTP status 204 is used for handleNotification
As SGP.22 states, the handleNotification endpoint uses HTTP status 204,
not 200 (due to its empty body).

Change-Id: I890bdbd3e1c4578d2d5f0367958fdce26e338cac
2024-07-17 18:37:02 +02:00
Harald Welte e18586ddf0 pySim.globalplatform: Add 'http' submodule for GP Amd B RAM over HTTPS
This implements the first parts of the "GlobalPlatform Remote
Application Management over HTTP Card Specification v2.3 - Amendment B,
Versoin 1.2".  Specifically, this patch covers the TLV definitions for
the OTA message used for HTTPS session triggering.

This also adds some more unit test coverage to pySim.cat, based on
real-world data that was captured nested inside the HTTPS Administration
session triggering parameters.

Change-Id: Ia7d7bd6df41bdf1249011bad9a9a38b7669edc54
2024-07-17 18:05:57 +02:00
Harald Welte 03194c0877 pySim.esim.es8p: Add support for encoding icon in ProfileMetadata
Change-Id: I8c6a0c628f07c2a9608174457d20b8955114731a
2024-07-17 18:05:57 +02:00
Harald Welte 84077f239f osmo-smdpp: Request enable/disable/delete notifications in metadata
this way, the eUICC will send us notifications whenever our profiles are
enabled/disabled/deleted.

Change-Id: I2861290864522b691b30b079c7c2e1466904df2d
2024-07-17 18:05:57 +02:00
Harald Welte 5370178ca2 osmo-smdpp: Implement 'other' notification signature validation
"other" notifications (enable, disable, delete) contain ECDSA
signatures that also need verification.

Change-Id: If610058b7af6f9fc7822576c93f9970e2ce9aba9
2024-07-17 18:05:57 +02:00
Harald Welte 3ad3da8995 contrib/es9p_client: Add support for reporting notifications to SM-DP+
The ES9+ interface is not only used for downloading eSIM profiles, but
it is also used to report back the installation result as well as
profile management operations like enable/disable/delete.

Change-Id: Iefba7fa0471b34eae30700ed43531a515af0eb93
2024-07-17 18:05:57 +02:00
Harald Welte 9d0c2947f1 es9p_client: Move code into a class; do common steps in constructor
This is in preparation of supporting more than just 'download'

Change-Id: I5a165efcb97d9264369a9c6571cd92022cbcdfb0
2024-07-17 15:22:09 +02:00
Harald Welte 0519e2b7e1 osmo-smdpp: Make sure to return empty HTTP response in handleNotification
SGP.22 is quite clear in that handleNotification shall return an empty
HTTP response body.  Let's make sure we comply to that and don't report
a JSON response.

Change-Id: I1cad539accbc3e7222bfd4780955b3b1ff694c5b
2024-07-17 15:22:09 +02:00
Harald Welte 96e2a521e9 pySim.esim.http_json_api: 'header' is not always present in response
For example, the ES9+ handleNotification function is defined with an
empty response body, so we cannot unconditionally assume that every HTTP
response will contain a JSON "header" value.

Change-Id: Ia3c5703b746c1eba91f85f8545f849a3f2d56e0b
2024-07-16 16:58:55 +00:00
Harald Welte 23dd13542e saip-tool: Fix output of TAR values in "print" subcommand
Change-Id: Ifba1048e3000829d54769b0420f5134e2f9b04e1
2024-07-16 15:06:57 +00:00
Harald Welte 5fdfa1463e pySim.cat: More spec references + explanations in comments
Change-Id: I4a89156075ae225594740451b33c3dec8983cf04
2024-07-15 12:40:10 +02:00
Harald Welte c805f00bff transport: Implement treatment of 62xx and 63xx warning/error responses
TS 102 221 specifies that (in case of a class 4 command) and as SW
62xx or 63xx, we should send a GET RESPONSE just like in the 61xx
case in order to get the respective response.

As we don't really know if it's a case1/2/3/4 command in the
pySim.transport, let's always send the GET RESPONSE in case SW 62xx or
63xx are received.  It shouldn't hurt - in the worst case there's no
response available...

Change-Id: Ibb1398194a16fc1f1f9bc46af6c66fb6575240cd
2024-07-13 23:09:02 +02:00
Harald Welte 12902730bf pySim.commands: Check return value of TERMINAL PROFILE command
Change-Id: Iaede74caf22970869c2c85b42d1e6f70d52c65cb
2024-07-13 23:07:22 +02:00
Harald Welte 0c40a2245b pySim.ota: Raise exception if encoded length would exceed 140 bytes
SMS cannot exceed 140 bytes, and TS 31.115 explicitly states that larger
messages must use multi-part SMS, which we don't yet implement here.

Change-Id: I8a1543838be2add1c3cfdf7155676cf2b9827e6e
2024-07-13 23:07:22 +02:00
Harald Welte dacacd206d pySim.ota: Handle cases where 'secured_data' is empty
while it's true that in situations where response_status == 'por_ok'
we are guaranteed to have a 'secured_data' key in the dict, its value
could well be b'', which in turn causes us to run into an exception,
calling a decoder on an empty byte value; let's avoid that.

Change-Id: I7c919f9987585d3b42347c54bd3082a54b8c2a0a
2024-07-13 23:07:22 +02:00
Harald Welte b865d383aa pySim.transport: Fix proactive_handler from_dict() calls
Change-Id: I2aa19ef6a19085d77c1b4f2d434a01ee241bd9a8
2024-07-13 23:04:20 +02:00
Harald Welte 1c2ec93164 pySim.tlv: Add COMPACT_TLV_IE TLV variant
the COMPACT-TLV variant is a TLV variant that ISO7816 uses for encoding
tag and length into a single octet. This is used (for example) in ATR
historical bytes.

Let's add support for this to our pySim TLV encoder/decoder.

Change-Id: I9e98d150b97317ae0c6be2366bdaaeaeddf8031c
2024-07-10 18:10:39 +02:00
Harald Welte 76b3488829 saip-tool: Also dump RFM information in "info" command
example output:

Number of RFM instances: 2
RFM instanceAID: d276000005aa060200000000b00000 (-> TAR: b00000)
        MSL: 0x16
RFM instanceAID: d276000005aa060200000000b00001 (-> TAR: b00001)
        MSL: 0x16
        ADF AID: a0000000871002ff33ffff8901010100

Change-Id: I534267c7420fc5bd96eaded6078e986161729073
2024-07-10 06:51:23 +00:00
Harald Welte 37320da4ab saip-tool: Dump information about security domains from "info" command
output looks like this:

Number of security domains: 1
Security domain Instance AID: a000000151000000
        KVN=0x01, KID=0x01, [SdKeyComp(type=aes, mac_len=8, data=00000000000000000000000000000000)]
        KVN=0x01, KID=0x02, [SdKeyComp(type=aes, mac_len=8, data=00000000000000000000000000000000)]
        KVN=0x01, KID=0x03, [SdKeyComp(type=aes, mac_len=8, data=00000000000000000000000000000000)]

Change-Id: Ia25f5ca6d7e888f7032301dd2561d066a3870010
2024-07-10 06:51:23 +00:00
Harald Welte b5679386d7 pySim.esim.saip: Add methods to rebuild "mandatory" lists in ProfileHeader
The ProfileHeader PE contain lists of template-oids and services that
are mandatory in this profile.  Let's add methods that can be used to
(re-) compute those lists based on the actual PE contents of the
sequence.

The idea is that during programmatic construction of a profile, those methods
would be called after appending all PEs, just before encoding the
profile as DER.

Change-Id: Ib43db8695c6eb63965756364fda7546d82df0beb
2024-07-10 06:51:23 +00:00
Harald Welte 03aebf5b43 pySim.esim.saip: ProfileElement{Header,End} classes
Change-Id: I88e18c1ee4907eeac3ae5d04d7bc30d6765f91fa
2024-07-10 06:51:23 +00:00
Harald Welte 5f9b8a8fc1 pySim.esim.saip: Move initialization of PE header to base class
Let's avoid the copy+paste in the subclass constructors and initialize the profile
element header in the base class constructor.

Change-Id: I6e69ae1f0d33d963247fc506db33b3840c10c19a
2024-07-10 06:51:23 +00:00
Harald Welte 3b7e2ae2c1 pySim.saip: Add ProfileElementRFM class
Change-Id: I547e02c12345932deafa4b914fcaeaa183b69798
2024-07-10 06:51:23 +00:00
Harald Welte 2668eb6148 pySim.esim.saip: Add ProfileElementOpt{USIM,ISIM} classes
Change-Id: Iebff2e767baa19f272eeddc62d7d5b3a8f665db5
2024-07-10 06:51:23 +00:00
Harald Welte 3c530c3c1a pySim.saip.oid: Properly differentiate optional from non-optional templates
There are e.g. templates for usim and for opt-usim, and they should not
be confused with each other.  Let's reflect that in the naming.

Change-Id: Ic6d04ce3172dc969c6b8c018b8d305eb6fd3f550
2024-07-10 06:51:23 +00:00