Recent versions of the ARA-M applet from Bertrand Martel can lock
the write access to ARA-M rules. Let's add a command for that and
some documentation.
Related: SYS#7245
Change-Id: I71581a0c9f146f9a0921093d9b53b053b4a8946c
The PE-Application object is used to provision JAVA-card applications
into an eUICC during profile installation. Let's extend the SAIP-tool
so that we are able to add, remove and inspect applications.
Change-Id: I41db96f2f0ccc29c1725a92215ce6b17d87b76ce
The application profile element has no ProfileElement class yet, so
let's create a ProfileElementApplication class and move the existing
extract-apps code into a method of ProfileElementApplication.
Change-Id: Iaa43036d388fbf1714c53cab1fc21092c4667a21
At the moment it is only possible to remove profile elements by their identification
number. However, there may be cases where we want to remove all profile elements of
a certain type at once (e.g. when removing all applications).
Change-Id: I92f9f9d5b4382242963f1b3ded814a0d013c4808
In some cases it may be helpful to extract a single profile element
from the sequence to a dedicated file.
Change-Id: I77a80bfaf8970660a84fa61f7e08f404ffc4c2da
To prevent code duplication and to make the implementation simpler,
let's add a function that takes care of writing the PE sequnece
to an output file.
Change-Id: I38733422270f5b9c18187b7f247b84bf21f9121b
A TransRecEF is based on a TransparentEF. This means that a TransRecEF
is basically normal TransparentEF that holds a record oriented data
structure. This also requires that the total length of the TransRecEF
is a multiple of the record length of the data structure that is stored
in it. When this is not the case, the last record will be cut short and
the decoding will fail. We should guard against this case.
Related: OS#6598
Change-Id: Ib1dc4d7ce306f1f0b080bb4b6abc36e72431d3fa
Startup scripts are executed using the cmd2 provided onecmd_plus_hooks
method. This method can run arbitrary commands, which also includes
the command "run_scrit" that we use to execute startup scripts.
When a script executes a quit command, or when someone issues a quit
command using the --execute-command or the command argument, then
this commands is executed. However a quit command won't actually quit
the process. All it does is to change the return code of
app.onecmd_plus_hooks (see [1]). So we must evaluate the return code
and take care of the quitting ourselves.
[1] https://cmd2.readthedocs.io/en/0.9.15/api/cmd.html#cmd2.cmd2.Cmd.onecmd_plus_hooks
Related: OS#6731
Change-Id: Ic6e9c54cdb6955d65011af3eb5a025eee5da4143
The implementations that inheret from the LinkBase class are expected to
implement a get_atr method. This method is mandatory, since it is one of
the most basic functionalities of pySim to display an ATR. Also the ATR
is sometimes needed to distinguish between different card models.
The modem_atcmd and calypso implementation completely lack the get_atr
method. Apparantly it is not possible to get an ATR in those
environments, so lets add a dummy method there.
Related: OS#6322
Change-Id: I4fc020ca45658af78e495a5c1b985213f83cbb50
The ATR constants are the only hex string constants where the hex
bytes digits are separated with spaces. Also the hex digits are in
lowercase. Let's use a lowercase string without spaces here like
we do in many other code locations.
Related: OS#6322
Change-Id: I95118115b02523ed262a2fbe4369ace3996cd8f5
Installing JAVA-card applets from a CAP file is a multi step process, which is
difficult when done manually. Fortunately it is easy to automate the process,
so let's add a dedicated command for that.
Change-Id: I6cbd37f0fad5579b20e83c27349bd5acc129e6d0
Related: OS#6679
The kvn parameter is used to select a keyset when establishin a secure channel.
At the moment this is a mandatory parameter and it must be within a certain
range.
However GPC_SPE_034 explicitly defines a reserved kvn value 0, that always
refers to the first available key. That effectively makes it an optional
parameter and the commandline interface should have the --key-ver parameter
as an optional parameter.
The ranges also have to be extended to allow 0 as kvn value. We also have to
put a range to support the sysmoUSIM-SJS1, which uses kvn value 1, which is
a non standard value.
Related: OS#6679
Change-Id: I42be2438c7f199b238f2ec7a9434cec5393210a7
To install JAVA-card applets we need to be able to extract the executeable
loadfile and the AIDs of the applet and the loadfile. This patch adds the
parser and related unittests.
Related: OS#6679
Change-Id: I581483ccb9d8a254fcecc995fec3c811c5cf38eb
The line with TAGS is longer than 120 columns and there is some
comment that should be moved to the python docstring.
Related: OS#6679
Change-Id: I1d02098320cfbe17a0eb1bfdcf3bc85034cc8e20
GPD_SPE_013 Table 6-3 defines two types of AID-REF-DO objects (both
are fully independed TLV IEs with the same name). The version with
tag '4F' identifies an SE application. It may contain an AID prefix
or even be of length 0 in case the rule should apply to all SE
applications. Then there is the version with tag 'C0', which must
always have length 0 and serves a flag to apply the rule to the
implicitly selected SE application. Technically both are completely
different things, so we must also treat them separately in the
pySim-shell code.
Related: OS#6681
Change-Id: I771d5e860b12215280e3d0a8c314ce843fe0d6a2
there are multiple references to a specification "SEID". As it seems this is
a reference to the GlobalPlatform "Secure Element Access Control" spec, which
has the document reference "GPD_SPE_013". Let's use "GPD_SPE_013" to referene
the spec.
Related: SYS#6681
Change-Id: I77895f1b84126563380ce89aa07a3b448d8784a3
Let's change the prompt from ">" to "#" when the user gains admin
privilegs using verify_adm.
Related: OS#6640
Change-Id: I957b9df7b5069b6fce5bf958c94e8ffda833c77f
When the equip method is running, all kinds of states in pySim-shell are reset.
To be sure that the card state is also reset (normally this is the case because
usually init_card is called before equip), we should send an explicit reset to
the card as well.
Related: OS#6640
Change-Id: I622a2df2c9184841f72abd18483bfbfd00b2f464
the testcase EF_ePDGSelection has a wrong testvector in the plmn field.
This test vector is accepted because there is a complementary error in
pyosmocom. However, the root problem got fixed (see depends), which means
that the test vector of EF_ePDGSelection now needs to be updated.
Depends: pyosmocom.git: I3811b227d629bd4e051a480c9622967e31f8a376
Change-Id: I96fd4c13c8e58ef33ddf9e3124617b1b59b9b2c1
Related: OS#6598
With osmo-remsim and Android APDU proxy we have two powerful solutions to
allow remote acces to UICC/eUICC cards. Let's add a section where we give
a brief overview about those solutions, so that pySim-shell users get
awre of them.
Related: OS#6367
Change-Id: I73de4de2e5d4a01d6d91989ee684cbdb680de8ef
The card initialization normally takes place automatically. Nearly all
testcases implicitly cover this code-path. However, it is also possible
to skip the card initialization and do it at some later point. This is
commonly the case for unprovisioned card that require some custom APDUs
in a basic initialization step. When this step is done one would use
the "equip" command to level up to the full featured mode. This patch
adds a testcase for this scenario
Related: OS#6367
Change-Id: I01a03fa07d8c62164453bd707c5943288ff1a972
ETSI TS 102 221, section 7.3 specifies that UICCs (and eUICCs) may support two
different transport protocols: T=0 or T=1 or both. The spec also says that the
terminal must support both protocols.
This patch adds the necessary functionality to support the T=1 protocol
alongside the T=0 protocol. However, this also means that we have to sharpen
the lines between APDUs and TPDUs.
As this patch also touches the low level interface to readers it was also
manually tested with a classic serial reader. Calypso and AT command readers
were not tested.
Change-Id: I8b56d7804a2b4c392f43f8540e0b6e70001a8970
Related: OS#6367
The _wrap_cmd_apdu methods for SCP02 and SCP03 are a bit hard to read. Let's
refactor them so that it is easier to understand what happens. In particular
that one can not have encryption (cenc) without signing (cmac)
Related: OS#6367
Change-Id: I4c5650337779a4bd1f98673650c6c3cb526d518b
Sphinx is complaining about a duplicate label "osmo-smdpp". Apparantly
because we use this label twices as section headline. The subsection
"osmo-smdpp" in "Running osmo-smdpp" talks about the commandline and the
supplementary files that osmo-smdpp needs to run. Let's split the two
topics into two different sections.
Change-Id: I8bc4979160a00d36a03b9cd10679562a08c2c55c
When a pySim-shell command is not recognized, cmd2 prints "xyz is not a
recognized command, alias, or macro." This string is a normal print out
and not an exception, but during tests, it may point out a severe problem
and therefore it should be tread like an exception.
Related: OS#6367
Change-Id: I17be6af1547b31170622e17b9cfb9c492597670d
by default pySim-shell does all kinds of probing and file selection
on startup. This is to determine the card type and to find a suitable
card profile. However, in case the card is non yet provisioned this
probing may cause a error messages and even might upset the cards
internal state. So let's have a commandline option thrugh which we
can instruct pySim-shell to skip any initialization and to give us
a prompt immediately, so that we can enter custom APDUs
Related: OS#6367
Change-Id: I1d8a57de201fe7ad7cbcbc6f72969ea8521e821d
There are situations where no card profile can be determined. In this case no
RuntimeState will be present. This is in particular the case when pySim-shell
is used on a card that is not provisioned/initialized yet. In those cases we
have to go the direct route and reset the card directly.
Related: OS#6367
Change-Id: I27bf9fdb131d8bdeba07f4dfd2b76b38f9bfdd17
The "apdu" command allows us to send custom APDUs to a card. This command is
often used in low level initialization scripts or tests. To stop the script
execution in case of an error, the command allows us to specify a status word
that must match the status word of the response. But we have no such mechanism
for the response itself. Let's add another parameter where we can pass a regex
that the response must match.
Related: OS#6367
Change-Id: I97bbcdf37bdcf00ad50a875b96940c211de7073d
When pySim-shell has problems starting up, it exits with an error
code. This is detected by the testsuite, but it also causes an
early exit, so that the log file content are not printed.
Change-Id: Ic0f34eda32a7c557810abcb05a84e343741fdb8a
when we sign and encrypt the APDU in _wrap_cmd_apdu (SCP03) we return an "mapdu"
at the end. However, in the (unlikely?) case where self.do_cencand
self.do_cmac are false, mapdu will be undeclared. In _wrap_cmd_apdu for SCP02
we just re-use the apdu variable and return it at the end, so when no
encryption and no signing is applied, the APDU falls just through without any
modifications. We should have the same mechanism for the SCP03 wrapping as
well.
Related: OS#6367
Change-Id: Ic7089a69dffd7313572c5b3e5953200be5925766
The tests that check the establishment of a secure channel currently only test
security level 3. Also the get_data command after it only tests data reception
from the card.
Let's extend the test coverage and test the SCP establishment for security
level 1 as well. Let's also add a get_status command to make sure sending data
to the card also works (without exceptions).
Related: OS#6367
Change-Id: Idff40b414a249e532df1bdce2a8deb9b0cb9718f
When we configure the tests to display file content, we only display files that
we compare, let's also display log file contents from pySim-shell. This will
be useful in situations where we only have log output from the tests, but no
access to the file system of the test host.
Related: OS#6601
Change-Id: Ibf6f78d7e71c213c7ca1caaf21c4c890e892261e
When pySim-shell is called by a testcase, a logfile is createted. The logfile
filename contains the testcase name. However, a testcase may run pySim-shell
multiple times. In this case we overwrite the log from previous run. Let's use a
counter to generate unique file names for each run, so that we won't lose logs
from previous runs.
Related: OS#6601
Change-Id: Ib2195d9b2231f74d0a6c4fb28f4889b6c45efb1e
When we get rid of temporary files, we delete those using a wildcard,
but for the logs from pySim-shell we explicitly memorize the name
of the pySim-shell logfile and delete it later by this explicit
name. This is not necessary, let's just delete all log files present
using a wildcard.
Related: OS#6601
Change-Id: I09dc7e59d1a3dcb68f54e3a8dccb86a1bc6c9ee6
When we use the argument parser with choices, we sometimes use a
list that we derive from a dictionary. However if we do that we
still must ensure that we really put a list and not a dict_values
or dict_keys class as parameter because this won't work any longer
with cmd2 version 2.5.0
Related: OS#6601
Change-Id: I165fefd8feb0d96cedc15d036fb32da381f711b3
The problems with test_list_and_rm_notif (see also change id
I7d0b6a998499d84f0eb4e24592ad43210ac54806) are now resolved, so
we can re-enable the testcase now.
Closes: SYS#7094
Change-Id: I95eb3b9c02a69653797851197e882ea9316805fc
The build system uses a virtual environment, in which it installs
pysim and its dependencies. This is done for the integration tests,
but not when building the sphinx documentation. However, the
documentation build process also invokes pysim code to generate
documentation from the docstrings. This means we need pysim with
all its dependencies for the doc building as well.
Change-Id: I6381eeef7fa19873ca0cc330a0ab43b7ef5096e4
Related: SYS#7094
Even though our tests are written in a way that they shouldn't interfere
with each other, it may happen that one testrun writes content to a file
that upsets a different testrun. The resulting problems are often
difficult to diagnose.
To minimize the problem, let's add code that can reset the cards to a
defined state. This can be done using pySim-shell's export
feature. We can generate a backup from a known good state and then play
back the backup to reset files that have been changed. Files that didn't
change will not be written thanks to the conserve_write feature of
pySim-shell.
Related: OS#4384
Change-Id: I42eaf61280968518164f2280245136fd30a603ce
We now have a construct based encoder/decoder for the record content
of EF.MSISDN. This means that we do not need the functions enc_msisdn
and dec_msisdn in the non-legacy code anymore. We can now move both
to legacy/utils.py.
Related: OS#5714
Change-Id: I19ec8ba14551ec282fc0cc12ae2f6d528bdfc527
The unittest for EF.DIR only runs with _test_decode, but it also runs with
_test_de_encode without any problems
Related: OS#5714
Change-Id: If459073c6ff927c1cc1790d506e3979243b1fb4c
The unittest for EF.CFIS only runs with _test_decode, but it also runs with
_test_de_encode without any problems
Related: OS#5714
Change-Id: Ib876fd799f871fe64ced2a7b64847ffd09e16ed9
The unittest for EF.ADN can run with _test_de_encode. However, the original
test vectors seem to be from a card with a slightly larger record size, so
they need a bit of re-alignment
Related: OS#5714
Change-Id: I241792e66ee6167be6ddc076453344b6307d6265
The encoding of EF.MSISDN is currently done with enc_msisdn and
dec_msisdn from utils.py. Let's replace this with a construct
based model, similar to the one we already use with EF.ADN
Related: OS#5714
Change-Id: I647f5c63f7f87902a86c0c5d8e92fdc7f4350a5a
Some methods sometimes have a **_kwargs parameter, let's be consistent
and use **kwargs only.
Related: OS#5714
Change-Id: I98857cc774185e55a604eb4fbfbf62ed4bd6ded7
In our construct models we frequently use a context parameter "total_len",
we also pass this parameter to construct when we decode files, but we
do not pass it when we generate files. This is a problem, because when
total_len is used in the construct model, this parameter must be known
also when decoding the file.
Let's make sure that the total_len is properly determined and and passed
to construct (via pyosmocom).
Related: OS#5714
Change-Id: I1b7a51594fbc5d9fe01132c39354a2fa88d53f9b
The testcase euicc.test_list_and_rm_notif fails due to a problem
with the eUICC. The eUICC reports the following error when a
delete notification attempt is made:
"delete_notification_status": "undefinedError"
Let's temporarily disable this testcase until the problem is resolved.
Change-Id: I7d0b6a998499d84f0eb4e24592ad43210ac54806
This patch adds a comprehensive testsuite for pySim-shell. The testsuite
is based on python's unittest framework in combination with pySim-shell
scripts.
Related: OS#6531
Change-Id: Ieae1330767a6e55e62437f5f988a0d33b727b5de
When a hexadecimal formatted ADM pin is retrieved via the
card_key_provider, it still requires the --pin-is-hex parameter so
that sanitize_pin_adm knows the correct format.
This unfortunately ruins the card_key_provider feature for all cards
that use hexadecimal pins, because the --pin-is-hex would also be
required in scripts, which makes a script either useable for cards
with hexadecimal ADM or for for cards with ASCII ADM.
To minimize the problem, let's recognize all ADM pins longer than 8
digits as hexadecimal in case --pin-is-hex is not set.
Related: OS#4348
Change-Id: Iad9398365d448946c499ce89e3cfb2c3af5d525e
Our test cards need to stay recognizable, so it is important that
each card has a unique ICCID. This means we must write an individual
ICCID, when we test writing the ICCID.
Related: OS#4384
Change-Id: I858a35e526e7b4868e901222d587258412779f41
The sysmoISIM-SJA2 does not support changing of the ICCID.
pySim-prog will also reject this, so let's remove the ICCID
from the parameter list.
Related: OS#4384
Change-Id: I89571f2bf7c4cec4d621c322a58687b7781b0ed2
Older construct versions seem to have problems, in particular with
evaluating COptional() correctly. With 2.10.70 no such problems
were observed.
Related: OS#5714
Change-Id: If59dc708a7194649d1f42c4cf33f6328edcb80d2
The "desc" command displays a string with a file description, let's also
display some size information as part of the description as well.
Related: OS#5714
Change-Id: I98e139ba2bf35df5524245cdd96f5c52cf09b986
We have an API function to get the number of records, let's now also
add API functions to get the record length and the overall size of
the currently selected file.
Related: OS#5714
Change-Id: Ica7811c04161d8098b40c7219ed6b939df716cfd
The documentation for the classic pySim-prog application is a bit
sparse. Let's rework it so that it includes the most important
information that is required to operate pySim-prog. Let's also add
a section about how the batch mode and CSV files are used.
Related: SYS#4120
Change-Id: I1d1a65154cea7fa77428b412fcf8c7b4cba629b1
The CSV mode needs one of the four additional parameters: --imsi
--iccid, --read-iccid or --read-imsi. Also this check is unrelated
to the batch mode. The CSV file parameter reading works independently
from the batch mode.
Related: SYS#4120
Change-Id: I1292afb85122ed2b7944d02ede69c928a453866f
When using a CSV file, we can either read the IMSI or ICCID from the
CSV file before programming. However, should also be possible to
supply both manually to identify the CSV file entry using the --imsi
or --iccid option. This currently only works for the IMSI, but not
for the ICCID.
Related: SYS#4120
Change-Id: Id3083c7794a7bd59501997f22afdc23bad3069e6
The writing to osmo-hlr SQLITE files is broken since the SQLITE format
has evolved over time. Let's add a FIXME note to tell that this needs
fixing.
Related: SYS#4120
Change-Id: I2b23f8bb9f3c2adeb48b010834057f5b4fb1e626
When we define positional arguments for the argument parser, we usually
use upper case letters only. However, there are some code locations that
use lower case letters. Let's translate those to capital letters to
have a consistent appeariance.
Related: OS#6531
Change-Id: Iec1ff8262bc6e9cf87c3cbf7b32fa5f753b7e574
The command cardinfo also displays the AIDs of the card applications.
However, on classic GSM sim cards there are no applications. In this
case cardinfo will still display the string 'AIDs:', but it will of
course not list any AIDs under this string.
Related: OS#6531
Change-Id: Ifb111ce43fdebe85d30857dfc61ab570380b68d1
The tutorial describes how SUCI calculation in the UE is configured,
let's now add a section about SUCI calculation by the USIM.
Related: OS#6531
Change-Id: I45d47f9278b30d99ebde6891de0ba8cc74b1a0a0
When pySim-shell is used in a scripted environment, we may easily get trapped in
the pySim-shell prompt. This may happen in particular in case the script file
is not executed due to problem with the reader initialization. In such a case
pySim-shell will not exit automatically and the shellscript that was calling
pySim-shell will stall indefinetly.
To make the use of pySim-shell more reliable in scripted environments, let's
add a --noprompt option that ensures the interactive mode is never entered.
Let's also exit with an appropriate return code in case of initialization
errors, so that the calling script can know that something went wrong.
Related: OS#6531
Change-Id: I07ecb27b37e2573629981a0d032cc95cd156be7e
The SimCardCommands has a cla_byte @property method, which automatically
returns the lchan patched CLA byte. We use cla_byte property to build
the UICC command APDUs inside SimCardCommands and then we hand the APDU
over to the send_apdu* methods. The cla_byte @property method as well
as the send_apdu* methods perform the lchan patching. This means the CLA
byte gets patched twice, which is technically not an issue, but can be
confusing when trying to understand the code.
To fix this, let's remove the @property methods and turn cla_byte into
a normal property again. This is also more accurate since the cla_byte
property originally was introduced to switch between UICC and classic
SIM APDU commands, which have almost identcal APDUs.
Related: OS#6531
Change-Id: I420f8a5f7ff8d9e5ef94d6519fb3716d6c7caf64
When probing for cards, the probing might fail in case the terminal
is empty. This results into lengthy error log output that is not
of interest.
Related: OS#6532
Change-Id: I1d44f9458a05992d79b0152d3affcfeb783cccff
When the test detects a card, but does not find the .data faile for
it, then it fails. This can be a problem in case we want to intentionally
exclude a specific card model.
Related: OS#6532
Change-Id: Iba196ada0076385de7bffcb157a85fda0a6c1852
The test currently expects all reader slots to be populated. This means
the cards may plugged into a random order, but there may not be any empty
slots in the system at all. This requirement is easy to meet when each
card has its own single-slot USB PCSC-reader, but as soon as multislot
readers are used there may be some empty slots.
Related: OS#6532
Change-Id: I7ba1d1350b6998d65e90408184accdb212556a7c
The section Technical References has direct download links for the relevant specs.
Then later in th Key Provisioning section another download link follows and another
one is redundant. Let's put all download links into the Technical References section
and then only use the spec numbers in the following. This way we have all download
links in one location.
Related: OS#6531
Change-Id: Ibcbc6bb5d836d32c381922a35afa3b73b5f90621
We currently have the shell script that performs the test in the
tests directory and the related data in pysim-testdata directory.
This is confusing, let's have evrything in a dedicated sub directory
Change-Id: Ic995a7f600d164fc0be3c2eb8255dbe043429bea
Related: OS#6531
We currently have the test data for pySim-trace in pysim-testdata.
This means we mix the test data with the data from our original
pySim integration tests. This is very confusing. Let's put the
test data and the testcase for pySim-trace into a dedicated
sub directory.
Change-Id: I565b4268a05c1a1334b5e7d3fbcd9ef2ef0f0c4c
Related: OS#6531
We currently mix the unit-tests with the shell script based integration
tests. Let's put them into a dedicated sub directory.
Related: OS#6531
Change-Id: I0978c5353d0d479a050bbb6e7ae5a63db5e08d24
The first hnet_pubkey value with the identifier 27 seems to be incorrect.
It differs from the value suggested in 3GPP TS 31.121, section 4.9.4 and
also does not work with the on card SUCI calculation.
The tutorial also contains a reference to 3GPP TS 33.501, Annex C.4. This
spec specifies an ECIES Profile A and an ECIES Profile B. The tutorial
recommends to use a key from profile B, but it actually uses a key from
profile A.
Related: OS#6531
Change-Id: I6fddf8a6efc28ad0d40b1715973429904e00d2b2
When creating the DES cipher object with DES.new, we use the property
card_keys.dek. This property may hold a 16 byte key, but DES uses
an 8 byte key (56 bit + 8 bit integrity). Pycryptodome does not
automatically ignore excess key bytes. Instead it throws an
exception. This means we need to make sure to supply only the first
8 bytes of card_keys.dek
See also: https://pycryptodome.readthedocs.io/en/latest/src/cipher/des.html
Related: OS#6531
Change-Id: I92e0dc6a6196b532bd8b53fca7b9e78070d6903f
The send_apdu* methods now support lchan patching, so there is no longer
a need for computing the class byte manually (which is prone get forgotten)
before calling a send_apdu*. It is now enough to supply an APDU that has
a class byte with the default channel selected. This also means we do not
need cla4lchan anymore, so let's restruture the code and get rid of it
completely.
Related: OS#6531
Change-Id: Ia795f3c16a8875484fce3b44e61497d5aa52b447
The ara_m commands use APDUs with a fix class byte (0x80). This means
that all ARA-M related features only work in the basic logical channel.
To fix this, let's compute the class byte for the current logical channel
dynamically inside the send_apdu methods of SimCardCommands. This will
fix the problem globally.
Related: OS#6531
Change-Id: Ie3e48678f178a488bfaea6cc2b9a3e18145a8d10
The argument parser object for establish_scp03 (est_scp03_parser) is
copied from est_scp02_parser. This object still has the .description
property set, which is the description for establish_scp02. To get
the description string that is defined in do_establish_scp03, we must
remove the old description string first.
Related: OS#6531
Change-Id: Ibb26bddf88b2e644a7f0c6b2a06bde228aa8afc7
The basic logical channel 0 is always present. It cannot be created or
closed. Let's restrict the value range of chan_nr, so that only valid
lchan numbers can be passed.
Related: OS#6531
Change-Id: I4eebd9f15fadd18e1caeb033fda36c59446fcab8
When we define command arguments using the ArgumentParser, we sometimes
define the positional arguments first. However, since positional arguments
usually follow after the optional (--xyz) arguments, we should define the
positional arguments last.
Related: OS#6531
Change-Id: I2412eb6e7dc32ae95a575f31d4489ce210d85ea0
When working with BER-TLF files, we can only delete one tag at a time.
There is no way to delete all tags at once. This may make working with
BER-TLV files difficult, in particular when scripting is used and the
script needs to start with an empty file. Also export has problems,
since it does not reset the file before setting the new values there
may be unexpected results in case there still tags in the file that
are not set during import. To fill the gap, let's add a commandd that
deletes all tags in a BER-TLV EF at once.
Related: OS#6531
Change-Id: I5d6bcfe865df7cb8fa6dd0052cab3b364d929f94
The CardKeyProvider support for the commands enable_chv, disable_chv,
verify_chv, change_chv and unblock_chv is broken. The reason for this
is the annotation "type=is_decimal" in the argument parser. This annotation
prevents the usage of string placeholders ("PIN1", "PUK1", etc).
Let's fix this by finding a better solution. We can also replace any
missing PIN/PUK code by checking if it is supplied or not. If not,
we query the CardKeyProvider. This also makes the usage of the *_chv
commands more uniform with the verify_adm command.
Related: OS#6531
Change-Id: I565b56ac608e801c67ca53d337bdec9efa3f3817