simtrace: Enable VCC detection via ADC (voltage dependent)

SIMtrace should reject any card activation at 1.8V as it is a 3[.3]V device
without level shifters.  For this, we must include the ADC in
determining the VCC voltage.

Change-Id: Ic76f06037590ff1c0dae818d5eb2c2019dd75f2d
FIXME: reporting uses raw ADC voltage, not the voltage before divider
This commit is contained in:
Harald Welte committed 2022-03-03 19:06:12 +01:00
1 parent 755387ee31
commit 09c279874e
1 file changed
+4
@@ -155,3 +155,7 @@
#endif
/* SIMtrace board supports man-in-the-middle mode */
//#define HAVE_MITM
#define DETECT_VCC_BY_ADC
#define VCC_UV_THRESH_1V8 (1500000/2) /* 10k/10k resistive divider halves voltage */
#define VCC_UV_THRESH_3V (2500000/2) /* 10k/10k resistive divider halves voltage */